Three-dimensional finite element analysis in distal en masse movement of the maxillary dentition with the multiloop edgewise archwire
- PMID: 15222721
- DOI: 10.1093/ejo/26.3.339
Three-dimensional finite element analysis in distal en masse movement of the maxillary dentition with the multiloop edgewise archwire
Abstract
The purpose of this study was to compare the effects of a multiloop edgewise archwire (MEAW) on distal en masse movement with a continuous plain ideal archwire (IA). Three-dimensional finite element models (FEM) of the maxillary dentition in which the second permanent molars had been extracted were constructed to include the periodontal membrane, alveolar bone, standard edgewise bracket (0.018 x 0.025 inch), stainless steel IA (0.016 x 0.022 inch), and MEAW (0.016 x 0.022 inch). The stress distribution and displacement of the maxillary dentition were analysed when Class II intermaxillary elastics (300 g/side) and 5 degree tip-back bends were applied to the IA and MEAW for distal en masse movement of the maxillary dentition. Compared with the IA, the MEAW showed that the discrepancy in the amount of tooth displacement was lower and individual tooth movement was more uniform and balanced. There was minimal vertical displacement or rotation of the teeth using the MEAW when compared with the IA. The MEAW seems to have advantages for distal en masse movement of the maxillary dentition.
Similar articles
-
Initial effect of multiloop edgewise archwire on the mandibular dentition in Class III malocclusion subjects. A three-dimensional finite element study.Eur J Orthod. 2008 Feb;30(1):10-5. doi: 10.1093/ejo/cjm098. Eur J Orthod. 2008. PMID: 18276927
-
[Three-dimensional finite element analysis of the biomechanical effects of multiloop edgewise archwire (MEAW)].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2005 Feb;22(1):86-90. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2005. PMID: 15762123 Chinese.
-
Maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3D finite element study.Prog Orthod. 2016 Dec;17(1):31. doi: 10.1186/s40510-016-0143-z. Epub 2016 Oct 3. Prog Orthod. 2016. PMID: 27667816 Free PMC article.
-
Multiloop edgewise archwire technique and denture frame analysis: a systematic review.Head Face Med. 2020 Nov 26;16(1):32. doi: 10.1186/s13005-020-00247-x. Head Face Med. 2020. PMID: 33243257 Free PMC article.
-
The value of the centre of rotation in initial and longitudinal tooth and bone displacement.Eur J Orthod. 2003 Jun;25(3):285-91. doi: 10.1093/ejo/25.3.285. Eur J Orthod. 2003. PMID: 12831219 Review.
Cited by
-
Torque Loss in En-Masse Retraction of Maxillary Anterior Teeth Using Miniimplants with Force Vectors at Different Levels: 3D FEM Study.J Clin Diagn Res. 2014 Dec;8(12):ZC77-80. doi: 10.7860/JCDR/2014/10099.5353. Epub 2014 Dec 5. J Clin Diagn Res. 2014. PMID: 25654038 Free PMC article.
-
The biomechanical effects of clear aligner trimline designs and extensions on orthodontic tooth movement: a systematic review.BMC Oral Health. 2024 Dec 20;24(1):1523. doi: 10.1186/s12903-024-05274-7. BMC Oral Health. 2024. PMID: 39707339 Free PMC article.
-
An investigation into structural behaviors of skulls chewing food in different occlusal relationships using FEM.Clin Exp Dent Res. 2020 Jun;6(3):277-285. doi: 10.1002/cre2.273. Epub 2019 Dec 20. Clin Exp Dent Res. 2020. PMID: 32558315 Free PMC article.
-
Is There a Need to Increase Palatal Root Torque of Upper Incisors in Lingual Appliance? A Finite Element Analysis.Contemp Clin Dent. 2020 Oct-Dec;11(4):320-326. doi: 10.4103/ccd.ccd_197_19. Epub 2020 Dec 20. Contemp Clin Dent. 2020. PMID: 33850396 Free PMC article.
-
Evaluation of Effects and Effectiveness of Various α and β Angulations for Three Different Loop Made of Stainless Steel Arch Wires - A FEM Study.J Clin Diagn Res. 2014 Jul;8(7):ZC33-7. doi: 10.7860/JCDR/2014/8941.4576. Epub 2014 Jul 20. J Clin Diagn Res. 2014. PMID: 25177634 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials