Comparative Study
. 1992 Aug;17(8 Suppl):S235-43.
doi: 10.1097/00007632-199208001-00004.

Biomechanical analysis of lumbosacral fixation

Affiliations
Comparative Study

Biomechanical analysis of lumbosacral fixation

D H McCord et al. Spine (Phila Pa 1976). 1992 Aug.

Abstract

Flexion testing was performed until failure on 66 lumbosacral bovine spinal segments comparing ten different lumbosacral instrumentation techniques. Maximum flexion moment at failure, flexural stiffness, and maximum angulation of the lumbosacral joint at failure were determined as well as strain measurements across the anterior aspect of the lumbosacral intervertebral disc using an extensometer. The maximum moment at failure was significantly greater for the only two devices that extended fixation into the ilium anterior to the projected image of the middle osteoligamentous column: ISOLA Galveston and ISOLA iliac screws (F = 12.2, P less than 0.001). The maximum stiffness at failure reinforced these findings (F = 23.7, P less than 0.001). A second subset of stability showed the advantages of S2 pedicle fixation by increasing the flexural lever arm (Cotrel-Dubousset butterfly plate, and Cotrel-Dubousset Chopin block, P less than 0.05). This exhaustive in vitro biomechanical study introduces the concept of a pivot point at the lumbosacral joint at the intersection of the middle osteoligamentous column (sagittal plane) and the lumbosacral intervertebral disc (transverse plane). A spinal surgeon can increase the stability of lumbosacral instrumentation by extending fixation through the anterior sacral cortex (Steffee plate group with pedicle screws that medially converge in a triangular fashion). A means of enhancing this fixation was to achieve more inferior purchase by extending the fixation down to the S2 pedicle (Cotrel-Dubousset Chopin and Cotrel-Dubousset butterfly groups). However, the best fixation was achieved by obtaining purchase between the iliac cortices down into the superior acetabular bone.(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

Similar articles

Cited by

Publication types