Determination of airborne anhydrides using LC-MS monitoring negative ions of di-n-butylamine derivatives
- PMID: 15237294
- DOI: 10.1039/b403408b
Determination of airborne anhydrides using LC-MS monitoring negative ions of di-n-butylamine derivatives
Abstract
An air sampling method for simultaneous determination of organic acid anhydrides and isocyanates is presented. Air samples are collected in impinger flasks filled with 0.01 M di-n-butylamine (DBA) in a mixture of toluene-acetonitrile (7:3, v/v) with a 13 millimetre glass fibre filter in series. The amount of anhydrides and isocyanates are determined as their amide and urea derivatives using LC-MS. Four anhydrides, maleic anhydride (MA), phthalic anhydride (PA), tetrahydrophthalic anhydride (TA) and cis-hexahydrophthalic anhydride (HA) and 11 isocyanates could be separated in 9 minutes using gradient elution. Anhydride-DBA derivatives in standard solutions were quantified using LC with chemiluminescent nitrogen detection (CLND). Anhydride-DBA derivatives were found to be stable for at least two months when stored in acetonitrile or toluene in the freezer. The yield of DBA derivatives of anhydrides in the 0.01 M DBA in toluene-acetonitrile (7:3, v/v) was in the range of 70->95%. Using MS and negative electrospray ionisation (ES-) linear calibrations curves were obtained for the anhydrides with correlation coefficients ranging from 0.9970-0.9997. The instrumental detection limit for the anhydrides ranged from 10-30 fmol, based on a signal to noise root mean square (RMS) ratio of 3. Monitoring positive and negative ions simultaneously, both isocyanates and anhydrides could be determined as their DBA derivatives in the same chromatographic run. When air samples were collected during thermal degradation of different coated metal sheets both anhydrides and isocyanates were present in the same samples and all the studied anhydrides were found.
Similar articles
-
Size-separated sampling and analysis of isocyanates in workplace aerosols. Part I. Denuder--cascade impactor sampler.Ann Occup Hyg. 2008 Jul;52(5):361-74. doi: 10.1093/annhyg/men017. Epub 2008 May 5. Ann Occup Hyg. 2008. PMID: 18458354
-
Validation of transferability of DBA derivatization and LC-MS/MS determination method for isocyanates via an interlaboratory comparison.Ann Occup Hyg. 2008 Nov;52(8):757-63. doi: 10.1093/annhyg/men057. Epub 2008 Sep 23. Ann Occup Hyg. 2008. PMID: 18812390
-
Determination of technical grade isocyanates used in the production of polyurethane plastics.J Environ Monit. 2004 Jul;6(7):606-14. doi: 10.1039/b402775b. Epub 2004 May 7. J Environ Monit. 2004. PMID: 15237291
-
Determination of amines as pentafluoropropionic acid anhydride derivatives in biological samples using liquid chromatography and tandem mass spectrometry.Analyst. 2004 Jun;129(6):522-8. doi: 10.1039/b403439b. Epub 2004 Apr 26. Analyst. 2004. PMID: 15152330
-
Dicarboxylic acid anhydrides as dissociating agents of protein-containing structures.Mol Cell Biochem. 1990 Sep 21;97(2):101-11. doi: 10.1007/BF00221051. Mol Cell Biochem. 1990. PMID: 2280759 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources