Comparative Study
. 2004 Jun;129(3):178-82.
doi: 10.1055/s-2004-822798.

[Impaired cerebral autoregulation in asymptomatic patients with carotid artery stenosis: comparison of acetazolamide-SPECT and transcranial CO(2)-dopplersonography]

[Article in German]
Affiliations
Comparative Study

[Impaired cerebral autoregulation in asymptomatic patients with carotid artery stenosis: comparison of acetazolamide-SPECT and transcranial CO(2)-dopplersonography]

[Article in German]
M Engelhardt et al. Zentralbl Chir. 2004 Jun.

Abstract

Purpose: The indication for operation in patients with asymptomatic high-grade carotid artery stenosis is still under debate. Since impaired cerebrovascular autoregulation is associated with an increased risk for ischaemic events, assessment of cerebral vascular reactivity might be a valuable selection criterion for surgery. The aim of our study was therefore to evaluate the incidence of impaired autoregulation in asymptomatic patients with acetazolamide-single photon emission computed tomography (ACZ-SPECT) and transcranial CO (2)-dopplersonography (CO (2)-TCD). Furthermore, both methods were compared in regard to results and clinical practicability.

Methods: In 42 patients with high-grade (> 70 %) asymptomatic carotid artery stenosis, cerebral perfusion and vascular reactivity were assessed with resting and ACZ-enhanced SPECT scans. In 31 of these patients the CO (2) reactivity of cerebral perfusion was determined by TCD and expressed as normalized autoregulation reserve (NAR).

Results: Cerebral perfusion was decreased in 14.3 %. In ACZ-SPECT 26 % and in CO (2)-TCD 28 % revealed an impaired vascular reactivity. Conformity of both methods was high (kappa = 0.93). TCD was superior in practicability, but only applicable in 81 % due to a missing temporal bone window for insonation.

Conclusion: In accordance ACZ-SPECT and CO (2)-TCD could detect impaired vascular reactivity in a quarter of asymptomatic patients. Both TCD and SPECT could be of value for preoperative selection in this group of patients, whereby sonography is recommended for daily diagnostic work-up.