[Multislice spiral CT (MSCT) in pediatric radiology: dose reduction for chest and abdomen examinations]
- PMID: 15237346
- DOI: 10.1055/s-2004-813198
[Multislice spiral CT (MSCT) in pediatric radiology: dose reduction for chest and abdomen examinations]
Abstract
The advent of multislice spiral CT (MSCT) technique has led to new aspects of dose reduction, especially for the dedicated use of MSCT in children. Optimizing pediatric MSCT protocols according to the clinical problem allows reduction of radiation exposure to a minimum without loss of diagnostic quality. The different parameters that influence the degree of dose reduction, like tube current-time product (mAs), tube voltage (kV), collimation and pitch, are discussed in context with previously published data and our own experience in nearly 200 pediatric CT examinations. In our department, the effective mAs is calculated for a pediatric chest MSCT by multiplication of the body weight in kilogram with a factor of 1 to 1.5 and for a pediatric abdominal MSCT by multiplication with a factor of 2 to 2.5. To calculate the equivalent effective dose for a contrast media-enhanced 80 kV protocol, the effective mAs of the 120 kV protocol can be multiplied by 2.7. A factor less than 2.7 means further dose reduction. Compared to the radiation exposure with a standard adult protocol, the effective dose in a pediatric thoracic MSCT could be reduced by up to 92 % in neonates, 89 % in toddlers and 80 % in school children. In abdominal MSCT, the effective dose could be reduced by up to 90 % in neonates, 89 % in toddlers and 83 % in school children. Using an adequate MSCT technique in children by adjusting the CT scanning parameters to the clinical question and body weight of the examined child enables a significant reduction of radiation exposure in comparison to standard MSCT protocols.
Similar articles
-
Usefulness of a method for changing tube current during helical scanning in multislice CT.Radiat Med. 2003 Sep-Oct;21(5):193-204. Radiat Med. 2003. PMID: 14632294
-
[Dose reduction in high-resolution MSCT examinations of the chest for early detection of pneumonia in immunocompromised patients].Rofo. 2009 Jun;181(6):549-55. doi: 10.1055/s-0028-1109190. Epub 2009 Mar 20. Rofo. 2009. PMID: 19306239 German.
-
Multidetector computed tomography chest examinations with low-kilovoltage protocols in adults: effect on image quality and radiation dose.J Comput Assist Tomogr. 2009 May-Jun;33(3):416-21. doi: 10.1097/RCT.0b013e318181fab5. J Comput Assist Tomogr. 2009. PMID: 19478637 Clinical Trial.
-
Pediatric abdominal applications of multidetector-row CT.Eur J Radiol. 2004 Oct;52(1):31-43. doi: 10.1016/j.ejrad.2004.03.031. Eur J Radiol. 2004. PMID: 15380845 Review.
-
[Value of electron beam tomography (EBT)].Rofo. 2004 Nov;176(11):1566-75. doi: 10.1055/s-2004-813666. Rofo. 2004. PMID: 15497074 Review. German.
Cited by
-
Value of virtual tracheobronchoscopy and bronchography from 16-slice multidetector-row spiral computed tomography for assessment of suspected tracheobronchial stenosis in children.Eur Radiol. 2006 Aug;16(8):1684-91. doi: 10.1007/s00330-006-0230-5. Epub 2006 Apr 19. Eur Radiol. 2006. PMID: 16622687
-
Diagnostic value of [(18)F]-FDG PET/CT in children with fever of unknown origin or unexplained signs of inflammation.Eur J Nucl Med Mol Imaging. 2010 Jan;37(1):136-45. doi: 10.1007/s00259-009-1185-y. Eur J Nucl Med Mol Imaging. 2010. PMID: 19526234
-
PET/CT in paediatric oncology: indications and pitfalls.Pediatr Radiol. 2009 Jun;39 Suppl 3:446-9. doi: 10.1007/s00247-009-1175-z. Pediatr Radiol. 2009. PMID: 19440764 Review. No abstract available.
-
Multidetector CT urography: experimental analysis of radiation dose reduction in an animal model.Eur Radiol. 2007 Sep;17(9):2318-24. doi: 10.1007/s00330-006-0565-y. Epub 2007 Feb 14. Eur Radiol. 2007. PMID: 17429649
-
Radiation protection in pediatric radiology.Dtsch Arztebl Int. 2011 Jun;108(24):407-14. doi: 10.3238/arztebl.2011.0407. Epub 2011 Jun 17. Dtsch Arztebl Int. 2011. PMID: 21776310 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources