Nasal conditioning in perennial allergic rhinitis after nasal allergen challenge
- PMID: 15248856
- DOI: 10.1111/j.1365-2222.2004.01996.x
Nasal conditioning in perennial allergic rhinitis after nasal allergen challenge
Abstract
Background: Antigen challenge in seasonal allergic rhinitis is considered to be associated with an increased ability of the nose to condition inspired air. In contrast, little is known about air conditioning after antigen challenge in perennial allergic rhinitis (PAR).
Objective: The aims of this study were to investigate whether antigen challenge in PAR changes nasal air conditioning and to assess the relationship between nasal conditioning and nasal patency and geometry.
Methods: Nineteen subjects with PAR were enrolled into this study. Measurement of nasal conditioning, active anterior rhinomanometry (AAR), acoustic rhinometry (AR), and clinical symptom evaluation were performed before and after nasal allergen challenge with allergen extracts from house dust mites.
Results: Ten and 20 min after nasal allergen challenge, the total water content of the air measured in the nasopharynx and the water gradient across the nose were significantly higher in the nasal cavity in which the allergen extract was sprayed. The temperature on both sides of the nose increased non-significantly after nasal allergen challenge. No correlation to data obtained by AAR, AR, and clinical symptom evaluation after nasal allergen challenge was found.
Conclusion: We suggest that an increase in mucosal humidity due to the allergic provocation might be responsible for the increase in nasal conditioning capacity because no correlation to changes in nasal perimeter and patency was found.
Similar articles
-
Natural and induced allergic responses increase the ability of the nose to warm and humidify air.J Allergy Clin Immunol. 2000 Dec;106(6):1045-52. doi: 10.1067/mai.2000.110472. J Allergy Clin Immunol. 2000. PMID: 11112885
-
Interleukin-8 secretion in patients with allergic rhinitis after an allergen challenge: interleukin-8 is not the main chemotactic factor present in nasal lavages.Clin Exp Allergy. 1997 Apr;27(4):379-88. Clin Exp Allergy. 1997. PMID: 9146930
-
Comparison of optical rhinometry to acoustic rhinometry using nasal provocation testing with Dermatophagoides farinae.Otolaryngol Head Neck Surg. 2010 Aug;143(2):290-3. doi: 10.1016/j.otohns.2010.02.034. Epub 2010 Jun 8. Otolaryngol Head Neck Surg. 2010. PMID: 20647137
-
Clinical trial design, nasal allergen challenge models, and considerations of relevance to pediatrics, nasal polyposis, and different classes of medication.J Allergy Clin Immunol. 2005 Mar;115(3 Suppl 1):S460-82. doi: 10.1016/j.jaci.2004.12.016. J Allergy Clin Immunol. 2005. PMID: 15746883 Review.
-
Nasal allergen challenge and mediators release.Allerg Immunol (Paris). 1997 Nov;29(9):269-71. Allerg Immunol (Paris). 1997. PMID: 9435923 Review.
Cited by
-
Acoustic rhinometry in nasal provocation test in perennial allergic rhinitis.Eur Arch Otorhinolaryngol. 2006 Oct;263(10):910-6. doi: 10.1007/s00405-006-0080-4. Epub 2006 Jul 1. Eur Arch Otorhinolaryngol. 2006. PMID: 16816933
-
Numerical simulation and nasal air-conditioning.GMS Curr Top Otorhinolaryngol Head Neck Surg. 2010;9:Doc08. doi: 10.3205/cto000072. Epub 2011 Apr 27. GMS Curr Top Otorhinolaryngol Head Neck Surg. 2010. PMID: 22073112 Free PMC article.
-
Upper airways reactions to cold air.Curr Allergy Asthma Rep. 2008 Apr;8(2):111-7. doi: 10.1007/s11882-008-0020-z. Curr Allergy Asthma Rep. 2008. PMID: 18417052 Review.
-
Effects of nasal mask leak and heated humidification on nasal mucosa in the therapy with nasal continuous positive airway pressure (nCPAP).Sleep Breath. 2008 Nov;12(4):353-7. doi: 10.1007/s11325-008-0173-y. Epub 2008 Mar 1. Sleep Breath. 2008. PMID: 18311494 Clinical Trial.