Abstract
The selection of patients for transcatheter or surgical closure of a secundum atrial septal defect requires accurate information regarding the anatomy of the defect such as its maximal diameter and the amount of circumferential tissue rim. Two-dimensional echocardiography is wanting as a means to define selection criteria for atrial septal defect closure. Since the defect is visualised from multiple orthogonal planes, maximal atrial septal defect diameter is widely under-estimated. The transcatheter approach measures the stretched diameter, but cannot be applied alone for patient selection since it does not provide information on the tissue rim. Three-dimensional echocardiography allows unique en face views of the atrial septum. Previous studies have shown the ability of 3-dimensional echocardiography to depict information regarding the shape, the maximal diameter and the rims surrounding the defect. Transthoracic 3-dimensional echocardiography is accurate to measure atrial septal defect maximal diameter and rims surrounding the defect. Such a non-invasive method could be applied to children selection for atrial septal defect closure. The transcatheter balloon method provides additional information such as the resistance of the septum. Device sizing and placement should take into account both 3-dimensional echocardiography and transcatheter findings.
Similar articles
-
Influence of atrial septal defect anatomy in patient selection and assessment of closure with the Cardioseal device; a three-dimensional transoesophageal echocardiographic reconstruction.Eur Heart J. 2000 Apr;21(7):573-81. doi: 10.1053/euhj.1999.1855. Eur Heart J. 2000. PMID: 10775012
-
Transthoracic three-dimensional echocardiography prior to closure of atrial septal defects in children.Cardiol Young. 2003 Feb;13(1):58-63. doi: 10.1017/s1047951103000118. Cardiol Young. 2003. PMID: 12691290
-
Transcatheter closure of secundum atrial septal defect using the Amplatzer Septal Occluder: initial results of a single medical center in Taiwan.Acta Paediatr Taiwan. 2005 Jan-Feb;46(1):17-23. Acta Paediatr Taiwan. 2005. PMID: 16302572 Clinical Trial.
-
Three-dimensional echocardiography of the atrial septum.Echocardiography. 2001 Jul;18(5):433-43. doi: 10.1046/j.1540-8175.2001.00433.x. Echocardiography. 2001. PMID: 11466156 Review.
-
Complex atrial septal defect closure in children.Rom J Morphol Embryol. 2019;60(1):49-57. Rom J Morphol Embryol. 2019. PMID: 31263827 Review.