Novel linear quadrupole ion trap/FT mass spectrometer: performance characterization and use in the comparative analysis of histone H3 post-translational modifications
- PMID: 15253445
- DOI: 10.1021/pr0499794
Novel linear quadrupole ion trap/FT mass spectrometer: performance characterization and use in the comparative analysis of histone H3 post-translational modifications
Abstract
We describe the design and performance of a prototype high performance hybrid mass spectrometer. This instrument consists of a linear quadrupole ion trap (QLT) coupled to a Fourier transform ion cyclotron resonance mass analyzer (FTMS). This configuration provides rapid and automated MS and MS/MS analyses, similar to the "data dependent scanning" found on standard 3-D Paul traps, but with substantially improved internal scan dynamic range, mass measurement accuracy, mass resolution, and detection limits. Sequence analysis of peptides at the zeptomole level is described. The recently released, commercial version of this instrument operates in the LC/MS mode (1 s/scan) with a mass resolution of 100 000 and is equipped with automatic gain control to provide mass measurement accuracy of 1-2 ppm without internal standard. Methodology is described that uses this instrument to compare the post-translational modifications present on histone H3 isolated from asynchronously growing cells and cells arrested in mitosis.
Similar articles
-
Performance evaluation of a dual linear ion trap-Fourier transform ion cyclotron resonance mass spectrometer for proteomics research.J Proteomics. 2013 Aug 2;88:109-19. doi: 10.1016/j.jprot.2013.04.009. Epub 2013 Apr 13. J Proteomics. 2013. PMID: 23590889 Free PMC article.
-
Extended Range Proteomic Analysis (ERPA): a new and sensitive LC-MS platform for high sequence coverage of complex proteins with extensive post-translational modifications-comprehensive analysis of beta-casein and epidermal growth factor receptor (EGFR).J Proteome Res. 2005 Jul-Aug;4(4):1155-70. doi: 10.1021/pr050113n. J Proteome Res. 2005. PMID: 16083266
-
Screening of synthetic PDE-5 inhibitors and their analogues as adulterants: analytical techniques and challenges.J Pharm Biomed Anal. 2014 Jan;87:176-90. doi: 10.1016/j.jpba.2013.04.037. Epub 2013 May 6. J Pharm Biomed Anal. 2014. PMID: 23721687 Review.
-
An automated high performance capillary liquid chromatography-Fourier transform ion cyclotron resonance mass spectrometer for high-throughput proteomics.J Am Soc Mass Spectrom. 2004 Feb;15(2):212-32. doi: 10.1016/j.jasms.2003.09.008. J Am Soc Mass Spectrom. 2004. PMID: 14766289
-
Triple quadrupole linear ion trap mass spectrometer for the analysis of small molecules and macromolecules.J Mass Spectrom. 2004 Aug;39(8):845-55. doi: 10.1002/jms.659. J Mass Spectrom. 2004. PMID: 15329837 Review.
Cited by
-
Library dependent LC-MS/MS acquisition via mzAPI/Live.Proteomics. 2013 May;13(9):1412-6. doi: 10.1002/pmic.201200583. Proteomics. 2013. PMID: 23457059 Free PMC article.
-
Proteomic solutions for analytical challenges associated with alcohol research.Alcohol Res Health. 2008;31(3):251-5. Alcohol Res Health. 2008. PMID: 23584870 Free PMC article. Review.
-
A dual pressure linear ion trap Orbitrap instrument with very high sequencing speed.Mol Cell Proteomics. 2009 Dec;8(12):2759-69. doi: 10.1074/mcp.M900375-MCP200. Epub 2009 Oct 14. Mol Cell Proteomics. 2009. PMID: 19828875 Free PMC article.
-
Modular mass spectrometric tool for analysis of composition and phosphorylation of protein complexes.PLoS One. 2007 Apr 4;2(4):e358. doi: 10.1371/journal.pone.0000358. PLoS One. 2007. PMID: 17406682 Free PMC article.
-
Chromatographic alignment of LC-MS and LC-MS/MS datasets by genetic algorithm feature extraction.J Am Soc Mass Spectrom. 2007 Oct;18(10):1835-43. doi: 10.1016/j.jasms.2007.07.018. Epub 2007 Jul 26. J Am Soc Mass Spectrom. 2007. PMID: 17720530
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources