Progress toward the development of an implantable sensor for glucose
- PMID: 1525989
Progress toward the development of an implantable sensor for glucose
Abstract
The development of an electrochemically based implantable sensor for glucose is described. The sensor is needle-shaped, about the size of a 28-gauge needle. It is flexible and must be implanted subcutaneously by using a 21-gauge catheter, which is then removed. When combined with a monitoring unit, this device, based on the glucose oxidase-catalyzed oxidation of glucose, reliably monitors glucose concentrations for as long as 10 days in rats. Various design considerations, including the decision to monitor the hydrogen peroxide produced in the enzymatic reaction, are discussed. Glucose constitutes the most important future target analyte for continuous monitoring, but the basic methodology developed for glucose could be applied to several other analytes such as lactate or ascorbate. The success in implementation of such a device depends on a reaction of the tissue surrounding the implant so as not to interfere with the proper functioning of the sensor. Histochemical evidence indicates that the tissue response leads to enhanced sensor performance.
Similar articles
-
Initial evaluation of a 290-microm diameter subcutaneous glucose sensor: glucose monitoring with a biocompatible, flexible-wire, enzyme-based amperometric microsensor in diabetic and nondiabetic humans.J Diabetes Complications. 1998 Nov-Dec;12(6):295-301. doi: 10.1016/s1056-8727(98)00011-7. J Diabetes Complications. 1998. PMID: 9877461
-
Murine model of implantable glucose sensors: a novel model for glucose sensor development.Diabetes Technol Ther. 2005 Oct;7(5):727-37; discussion 738-40. doi: 10.1089/dia.2005.7.727. Diabetes Technol Ther. 2005. PMID: 16241876
-
[Subcutaneously implantable glucose sensors in patients with diabetes mellitus; still many problems].Ned Tijdschr Geneeskd. 2002 Jul 13;146(28):1313-6. Ned Tijdschr Geneeskd. 2002. PMID: 12148218 Review. Dutch.
-
Enhancing the sensitivity of needle-implantable electrochemical glucose sensors via surface rebuilding.J Diabetes Sci Technol. 2013 Mar 1;7(2):441-51. doi: 10.1177/193229681300700221. J Diabetes Sci Technol. 2013. PMID: 23567003 Free PMC article.
-
Towards smart tattoos: implantable biosensors for continuous glucose monitoring.Adv Healthc Mater. 2013 Jan;2(1):43-56. doi: 10.1002/adhm.201200167. Epub 2012 Nov 26. Adv Healthc Mater. 2013. PMID: 23184404 Review.
Cited by
-
Evaluation of the tissue reaction to a percutaneous access device using titanium fibre mesh anchorage in goats.J Mater Sci Mater Med. 1998 Sep;9(9):523-8. doi: 10.1023/a:1008840022016. J Mater Sci Mater Med. 1998. PMID: 15348850
-
Biomaterials/tissue interactions: possible solutions to overcome foreign body response.AAPS J. 2010 Jun;12(2):188-96. doi: 10.1208/s12248-010-9175-3. Epub 2010 Feb 9. AAPS J. 2010. PMID: 20143194 Free PMC article. Review.
-
[Design and implementation of real-time continuous glucose monitoring instrument].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2017 Dec 1;34(6):949-957. doi: 10.7507/1001-5515.201607016. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2017. PMID: 29761993 Free PMC article. Chinese.
-
Neurometabolic coupling between neural activity, glucose, and lactate in activated visual cortex.J Neurochem. 2015 Nov;135(4):742-54. doi: 10.1111/jnc.13143. Epub 2015 May 29. J Neurochem. 2015. PMID: 25930947 Free PMC article.
-
Electrochemical sensor array for glucose monitoring fabricated by rapid immobilization of active glucose oxidase within photochemically polymerized hydrogels.J Diabetes Sci Technol. 2007 May;1(3):366-71. doi: 10.1177/193229680700100308. J Diabetes Sci Technol. 2007. PMID: 19885091 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Other Literature Sources
Medical