Abstract
Heterophilic antibodies interfere in two-site immunoassays. Our purpose was to screen for the samples containing heterophilic antibodies that react with mouse immunoglobulins and to use them to determine how to eliminate interference in various two-site immunoassays being developed in our laboratory. Of approximately 2600 samples screened, 81 had heterophilic antibodies. When creatine kinase MB (CKMB) concentration was measured with intact antibody conjugate in these 81 samples, 18 (22%) samples had apparent CKMB values significantly greater than values measured with Hybritech's "Tandem -E CKMB immunoenzymetric" assay and Corning agarose-gel electrophoresis. Adding up to 133 mg/L of polymerized IgG or up to 1666 mg/L polyclonal mouse IgG in the assay did not eliminate the interference in all the samples. However, adding F(ab')2 conjugate plus 40 mg/L of polymerized IgG or 83 mg/L of polyclonal mouse IgG eliminated the interference in all the samples. This approach was also effective in eliminating the interference in 15 samples containing 4.7-165.2 mg/L of human antimouse antibody (HAMA). Combined use of F(ab')2 conjugate and polyclonal mouse IgG is recommended to eliminate interference from heterophilic antibodies that react with murine immunoglobulins or HAMA in two-site murine-antibody-based assays.
Similar articles
-
Eliminating heterophilic antibody interference for ferritin detection using Olympus F(ab')2 based reagent.Clin Lab. 2008;54(9-10):355-7. Clin Lab. 2008. PMID: 19097493
-
Human heterophilic antibodies display specificity for murine IgG subclasses.Clin Biochem. 2005 May;38(5):465-72. doi: 10.1016/j.clinbiochem.2005.02.008. Clin Biochem. 2005. PMID: 15820778
-
Different efficacy of various blocking reagents to eliminate interferences by human antimouse antibodies with a two-site immunoassay.Clin Biochem. 1996 Apr;29(2):145-8. doi: 10.1016/0009-9120(95)02044-6. Clin Biochem. 1996. PMID: 8601323
-
Heterophilic antibody interference in immunometric assays.Best Pract Res Clin Endocrinol Metab. 2013 Oct;27(5):647-61. doi: 10.1016/j.beem.2013.05.011. Epub 2013 Jun 20. Best Pract Res Clin Endocrinol Metab. 2013. PMID: 24094636 Review.
-
Antibody multispecificity in immunoassay interference.Clin Biochem. 1992 Apr;25(2):77-87. doi: 10.1016/0009-9120(92)80048-l. Clin Biochem. 1992. PMID: 1623581 Review.
Cited by
-
Avian IgY antibodies and their recombinant equivalents in research, diagnostics and therapy.Biologicals. 2012 Sep;40(5):313-22. doi: 10.1016/j.biologicals.2012.05.003. Epub 2012 Jun 28. Biologicals. 2012. PMID: 22748514 Free PMC article. Review.
-
False serum calcitonin high levels using a non-competitive two-site IRMA.J Endocrinol Invest. 2001 May;24(5):356-60. doi: 10.1007/BF03343873. J Endocrinol Invest. 2001. PMID: 11407656
-
Potential false-positive reasons for SARS-CoV-2 antibody testing and its solution.J Med Virol. 2021 Jul;93(7):4242-4246. doi: 10.1002/jmv.26937. Epub 2021 Mar 25. J Med Virol. 2021. PMID: 33710634 Free PMC article. Review.
-
Simultaneous detection of Human Immunodeficiency Virus 1 and Hepatitis B virus infections using a dual-label time-resolved fluorometric assay.J Nanobiotechnology. 2010 Nov 26;8:27. doi: 10.1186/1477-3155-8-27. J Nanobiotechnology. 2010. PMID: 21108849 Free PMC article.
-
Development of a dual antigen lateral flow immunoassay for detecting Yersinia pestis.PLoS Negl Trop Dis. 2022 Mar 23;16(3):e0010287. doi: 10.1371/journal.pntd.0010287. eCollection 2022 Mar. PLoS Negl Trop Dis. 2022. PMID: 35320275 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Miscellaneous