Current trends in managing the anophthalmic socket after primary enucleation and evisceration
- PMID: 15266140
- DOI: 10.1097/01.iop.0000129528.16938.1e
Current trends in managing the anophthalmic socket after primary enucleation and evisceration
Abstract
Purpose: To evaluate current trends in the management of the anophthalmic socket after primary enucleation and evisceration.
Methods: The active membership of the American Society of Ophthalmic Plastic and Reconstructive Surgery (ASOPRS) was surveyed regarding primary enucleations and eviscerations performed between January and December 2002. Survey questions included practice demographics, orbital implant use, wrapping materials, placement of a motility peg, reasons for implant choice, and complications encountered.
Results: A total of 2,779 primary orbital implants were reported, comprising 1,919 (69.1%) enucleations and 860 (30.9%) eviscerations. The high-density porous polyethylene implant was used most frequently for enucleations (42.7%), followed by coralline hydroxyapatite (27.3%) and nonporous alloplastic implants (19.9%). For eviscerations, the high-density porous polyethylene implant was the most commonly used implant (42.3%), followed by hydroxyapatite (25.9%) and nonporous alloplastic implants (25.7%). The top 3 reasons for implant choice were outcome (69.3%), cost (43.6%), and experience (39.5%). Most implants were either not wrapped (59.8%) or were wrapped in donor sclera (25.2%) or polyglactin mesh (7.2%). Pegs were used in 8.1% of all implants reported. The most frequent complications encountered for unpegged implants were exposure (3.2%) and infection (0.4%). For pegged implants, the most common complications reported were pyogenic granuloma (13.7%), exposure (5.7%), and discharge (5.7%).
Conclusions: In managing the anophthalmic socket, ASOPRS survey respondents preferred to use the porous polyethylene implant after primary enucleation and evisceration. Most orbital implants were not wrapped, and most surgeons preferred not to place a motility post or peg in the implant.
Similar articles
-
UK national survey of enucleation, evisceration and orbital implant trends.Br J Ophthalmol. 2007 May;91(5):616-9. doi: 10.1136/bjo.2006.103937. Epub 2006 Dec 6. Br J Ophthalmol. 2007. PMID: 17151061 Free PMC article.
-
Exposure rate of hydroxyapatite orbital implants a 15-year experience of 802 cases.Ophthalmology. 2008 Mar;115(3):566-572.e2. doi: 10.1016/j.ophtha.2007.06.014. Epub 2007 Sep 14. Ophthalmology. 2008. PMID: 17854900
-
Porous and nonporous orbital implants for treating the anophthalmic socket: A meta-analysis of case series studies.Orbit. 2016;35(2):78-86. doi: 10.3109/01676830.2016.1139591. Epub 2016 Feb 29. Orbit. 2016. PMID: 26928263
-
Anophthalmic socket: choice of orbital implants for reconstruction.Arq Bras Oftalmol. 2015 Jul-Aug;78(4):260-3. doi: 10.5935/0004-2749.20150068. Arq Bras Oftalmol. 2015. PMID: 26375346 Review.
-
Current techniques of enucleation: a survey of 5,439 intraorbital implants and a review of the literature.Ophthalmic Plast Reconstr Surg. 1995 Jun;11(2):77-86; discussion 87-8. Ophthalmic Plast Reconstr Surg. 1995. PMID: 7654621 Review.
Cited by
-
Single or double? A comparison of evisceration techniques.Int Ophthalmol. 2023 Jun;43(6):1811-1817. doi: 10.1007/s10792-022-02578-x. Epub 2022 Dec 8. Int Ophthalmol. 2023. PMID: 36482132
-
Indications and results in anophthalmic socket reconstruction using dermis-fat graft.Clin Ophthalmol. 2015 May 4;9:795-9. doi: 10.2147/OPTH.S77948. eCollection 2015. Clin Ophthalmol. 2015. PMID: 25999688 Free PMC article.
-
Polyester 5-0 suture for porous implant placement after retinoblastoma enucleation: analysis of 120 sockets.BMC Ophthalmol. 2023 Jan 23;23(1):30. doi: 10.1186/s12886-023-02787-7. BMC Ophthalmol. 2023. PMID: 36690980 Free PMC article.
-
Comparison between local-made and imported porous polyethylene orbital implant: a randomized controlled equivalence trial and multicenter study.Int J Ophthalmol. 2024 Oct 18;17(10):1857-1863. doi: 10.18240/ijo.2024.10.12. eCollection 2024. Int J Ophthalmol. 2024. PMID: 39430012 Free PMC article.
-
Low-cost three-dimensional printed orbital template-assisted patient-specific implants for the correction of spherical orbital implant migration.Indian J Ophthalmol. 2018 Nov;66(11):1600-1607. doi: 10.4103/ijo.IJO_472_18. Indian J Ophthalmol. 2018. PMID: 30355870 Free PMC article.