Abstract
Aim: Most of dental operators agree about a gengival retraction impregnated cord in order to obtain an accurate and overwide dental impression. Hemostatic agents allow the formation of the primary coagulum that determines/causes the retraction of gum connective. Sometimes these astringent liquids cause local inflammation reaction as reported in literature. Aim of this work was the evaluation of the cytotoxic and inflammatory action of the most common astringent liquid on human gum primary cells by in vitro tests.
Methods: For this purpose primary cultures of normal human oral keratinocytes were established, following used either as monolayer or as reconstituted model. All dental preparations were dissolved in CEC medium, diluted to the designed concentrations and applied to the cultured cells. The cytotoxicity was determined by using MTT test, able to evaluate the succinate dehydrogenase activity and therefore the cell viability. Control cultures were treated with CED alone, whereas sodium dodecyl sulphate (SDS) was used as a positive control. Furthermore, the inflammatory response, determined by measuring TNF-alpha and IFN-gamma release, was evaluated on a reconstituted multilayer human oral epidermis model.
Results: All agents tested showed a dose-dependent increase in the cytotoxicity to normal human gingival keratinocytes over the dose range examined. In particular the results obtained suggest the higher toxicity of the Astringedent X compound.
Conclusion: The results obtained from the present studies not only provide useful estimates of relative toxicities of these preparations to human oral mucose, but also can be useful as a standard for cytotoxic and inflammatory assessment of newly developed dental preparations to be topically applied to the oral mucosa. It is important to note, however, that the interpolation of these findings to in vivo conditions remains to be done.
Similar articles
-
Safety and nutritional assessment of GM plants and derived food and feed: the role of animal feeding trials.Food Chem Toxicol. 2008 Mar;46 Suppl 1:S2-70. doi: 10.1016/j.fct.2008.02.008. Epub 2008 Feb 13. Food Chem Toxicol. 2008. PMID: 18328408 Review.
-
Final report of the safety assessment of Alcohol Denat., including SD Alcohol 3-A, SD Alcohol 30, SD Alcohol 39, SD Alcohol 39-B, SD Alcohol 39-C, SD Alcohol 40, SD Alcohol 40-B, and SD Alcohol 40-C, and the denaturants, Quassin, Brucine Sulfate/Brucine, and Denatonium Benzoate.Int J Toxicol. 2008;27 Suppl 1:1-43. doi: 10.1080/10915810802032388. Int J Toxicol. 2008. PMID: 18569160 Review.
-
Beta-cell function and mass in type 2 diabetes.Dan Med Bull. 2009 Aug;56(3):153-64. Dan Med Bull. 2009. PMID: 19728971
-
Gingival inflammatory response induced by chemical retraction agents in beagle dogs.Int J Prosthodont. 2002 Jan-Feb;15(1):14-9. Int J Prosthodont. 2002. PMID: 11887594
-
Final report on the safety assessment of capsicum annuum extract, capsicum annuum fruit extract, capsicum annuum resin, capsicum annuum fruit powder, capsicum frutescens fruit, capsicum frutescens fruit extract, capsicum frutescens resin, and capsaicin.Int J Toxicol. 2007;26 Suppl 1:3-106. doi: 10.1080/10915810601163939. Int J Toxicol. 2007. PMID: 17365137 Review.
Cited by
-
Biological Response Induced in Primary Human Gingival Fibroblasts upon Exposure to Various Types of Injectable Astringent Retraction Agents.Materials (Basel). 2021 Apr 20;14(8):2081. doi: 10.3390/ma14082081. Materials (Basel). 2021. PMID: 33924145 Free PMC article.
-
Bleeding Index and Monocyte Chemoattractant Protein 1 as Gingival Inflammation Parameters after Chemical-Mechanical Retraction Procedure.Med Princ Pract. 2020;29(5):492-498. doi: 10.1159/000506878. Epub 2020 Apr 2. Med Princ Pract. 2020. PMID: 32241014 Free PMC article.
-
Determination of Gingival Index and Salivary Proinflammatory Cytokines (Interleukin 6 and Tumour Necrosis Factor α) After Chemical-Mechanical Retraction Procedure.Diagnostics (Basel). 2025 Feb 10;15(4):424. doi: 10.3390/diagnostics15040424. Diagnostics (Basel). 2025. PMID: 40002575 Free PMC article.