Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2004 Aug;99(2):584-8, table of contents.
doi: 10.1213/01.ANE.0000122823.50592.C9.

Nerve stimulator-assisted evoked motor response predicts the latency and success of a single-injection sciatic block

Affiliations
Clinical Trial

Nerve stimulator-assisted evoked motor response predicts the latency and success of a single-injection sciatic block

Radha Sukhani et al. Anesth Analg. 2004 Aug.

Abstract

Variable onset latency of single-injection sciatic nerve block (SNB) may result from drug deposition insufficiently close to all components of the nerve. We hypothesized that this variability is caused by the needle tip position relative to neural components, which is objectified by the type of evoked motor response (EMR) elicited before local anesthetic injection. One-hundred ASA I-II patients undergoing reconstructive ankle surgery received infragluteal-parabiceps SNB using 0.4 mL/kg (maximum 35 mL) of levobupivacaine 0.625%. The end-point for injection was the first elicited EMR: inversion (I), plantar flexion (PF), dorsiflexion (DF), or eversion (E) at 0.2-0.4 mA. The frequencies of the EMRs were: I 40%, PF 43%, E 14%, and DF 3%. SNB was considered complete if both tibial and common peroneal nerves were blocked and failed if either analgesia to pinprick was not observed at 30 min or anesthesia at 60 min. Patients with an EMR of I demonstrated shorter mean times (+/-95% confidence interval [CI]) to complete the block with 8.5 (95% CI, 6.2-10.8) min compared to 27.0 (95% CI, 20.6-33.4) min after PF (P < 0.001) and 30.4 (95% CI, 24.9-35.8) min after E (P < 0.001). No rescue blocks were required in group I compared with 24% (P = 0.001) and 71% (P < 0.001) of patients in groups PF and E, respectively. We conclude that EMR type during nerve stimulator-assisted single-injection SNB predicts latency and success of complete SNB because the observed EMR is related to the positioning of the needle tip relative to the tibial and common peroneal nerves.

PubMed Disclaimer

Publication types

Substances

LinkOut - more resources