The effects of ionisation density on the thermoluminescence response (efficiency) of LiF:Mg,Ti and LiF:Mg,Cu,P
- PMID: 15273352
- DOI: 10.1093/rpd/nch310
The effects of ionisation density on the thermoluminescence response (efficiency) of LiF:Mg,Ti and LiF:Mg,Cu,P
Abstract
In this paper, the various models dealing with the effects of ionisation density on the thermoluminescence (TL) response (efficiency) of TL LiF dosemeters are discussed. These include (i) the Unified Interaction Model (UNIM), which models photon/electron linear/supralinear dose response; (ii) the Extended Track Interaction Model (ETIM), which models heavy charged particle (HCP) TL fluence response; (iii) Modified Track Structure Theory (MTST), which models relative HCP TL efficiencies; and (iv) Microdosimetric Target Theory (MTT), which models both relative HCP efficiencies and photon energy response.
Similar articles
-
Optical excitation of LiF:Mg,Ti following alpha and beta irradiation.Radiat Prot Dosimetry. 2006;119(1-4):386-9. doi: 10.1093/rpd/nci590. Epub 2006 Apr 3. Radiat Prot Dosimetry. 2006. PMID: 16585263
-
Alpha particle and proton relative thermoluminescence efficiencies in LiF:Mg,Cu,P:is track structure theory up to the task?Radiat Prot Dosimetry. 2012 Jul;150(3):359-74. doi: 10.1093/rpd/ncr406. Epub 2011 Oct 31. Radiat Prot Dosimetry. 2012. PMID: 22042968
-
Energy responses of the LiF series TL pellets to high-energy photons in the energy range from 1.25 to 21 MV.Radiat Prot Dosimetry. 2006;119(1-4):353-6. doi: 10.1093/rpd/nci627. Epub 2006 Apr 27. Radiat Prot Dosimetry. 2006. PMID: 16644960
-
The application of LiF:Mg,Cu,P to large scale personnel dosimetry: current status and future directions.Radiat Prot Dosimetry. 2006;119(1-4):248-54. doi: 10.1093/rpd/nci692. Epub 2006 Jul 11. Radiat Prot Dosimetry. 2006. PMID: 16835277 Review.
-
Theories of TL systems: failures, successes, conflicts, trends: insights into possible future materials and techniques.Radiat Prot Dosimetry. 2006;119(1-4):124-9. doi: 10.1093/rpd/nci695. Epub 2006 Apr 3. Radiat Prot Dosimetry. 2006. PMID: 16585259 Review.
Cited by
-
Thermoluminescence solid-state nanodosimetry--the peak 5A/5 dosemeter.Radiat Prot Dosimetry. 2011 Feb;143(2-4):416-26. doi: 10.1093/rpd/ncq479. Epub 2010 Dec 13. Radiat Prot Dosimetry. 2011. PMID: 21149323 Free PMC article.
-
Mysteries of LiF TLD response following high ionisation density irradiation: nanodosimetry and track structure theory, dose response and glow curve shapes.Radiat Prot Dosimetry. 2011 Jun;145(4):356-72. doi: 10.1093/rpd/ncq381. Epub 2010 Nov 24. Radiat Prot Dosimetry. 2011. PMID: 21106636 Free PMC article.
-
Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part I. Electronic brachytherapy source.Med Phys. 2014 Feb;41(2):022103. doi: 10.1118/1.4862505. Med Phys. 2014. PMID: 24506635 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous