Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2004 Aug 1;59(5):1446-53.
doi: 10.1016/j.ijrobp.2004.01.001.

Evaluation of a radiotherapy protocol based on INT0116 for completely resected gastric adenocarcinoma

Affiliations

Evaluation of a radiotherapy protocol based on INT0116 for completely resected gastric adenocarcinoma

Hans T Chung et al. Int J Radiat Oncol Biol Phys. .

Abstract

Purpose: With the results of the INT0116 study, adjuvant radiochemotherapy has become the standard treatment after complete resection of gastric adenocarcinoma. However, the implementation of radiotherapy (RT) remains a concern. In response, consensus guidelines on RT technique have been published. Our objective was to measure the inter- and intraclinician variability in RT field delineation using conventional two- (2D) and three-dimensional (3D) techniques.

Methods and materials: Between 1999 and 2003, five radiation oncologists (ROs) treated 45 patients with completely resected, gastric adenocarcinoma using postoperative radiochemotherapy (INT0116). Two cases were included in this study (Patient 1 had cardia and Patient 2 had antral disease). Standardized vignettes (with surgical and pathologic findings) and preoperative and postoperative imaging for each case were developed. Each RO designed AP-PA fields for each patient (2D planning) on two separate occasions. This was repeated using a 3D planning technique.

Results: Patient 1 had a mean field area of 250.2 cm(2) (SD 12.0) and 227.9 cm(2) (SD 26.5) using 2D and 3D planning, respectively (p = 0.03). The mean clinical target volume (CTV) volume was 468.3 cm(3) (SD 65.9). Patient 1 had a significantly greater inter- than intra-RO variation for the field area designed with 3D planning; however, no difference occurred with 2D planning or CTV contouring. Patient 2 had a mean field area of 234.8 cm(2) (SD 33.1) and 226.8 cm(2) (SD 19.3) using 2D and 3D planning, respectively (p = 0.5). The mean CTV was 729.4 cm(3) (SD 67.3). For Patient 2, the inter-RO variability was significantly greater than the intra-RO variability for the field area using both 2D and 3D planning, and no difference was seen for the CTV. Composite beam's-eye-view plots revealed that the superior, inferior, and right lateral borders proved to be most contentious.

Conclusion: Despite published guidelines and a departmental protocol, significant variations in the RT field areas were seen among ROs for both 2D and 3D planning. However, in general, CTV contouring was reproducible. Because 3D-RT hinges on accurate target identification, caution should be exercised before migrating to 3D planning for postoperative gastric cancer.

PubMed Disclaimer

Publication types

LinkOut - more resources