Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2004 Aug 10;110(6):756-62.
doi: 10.1161/01.CIR.0000138103.91187.E3. Epub 2004 Jul 26.

Carotid plaque echolucency increases the risk of stroke in carotid stenting: the Imaging in Carotid Angioplasty and Risk of Stroke (ICAROS) study

Affiliations
Free article

Carotid plaque echolucency increases the risk of stroke in carotid stenting: the Imaging in Carotid Angioplasty and Risk of Stroke (ICAROS) study

Giorgio M Biasi et al. Circulation. .
Free article

Abstract

Background: Carotid artery stenting (CAS) has recently emerged as a potential alternative to carotid endarterectomy. Cerebral embolization is the most devastating complication of CAS, and the echogenicity of carotid plaque has been indicated as one of the risk factors involved. This is the first study to analyze the role of a computer-assisted highly reproducible index of echogenicity, namely the gray-scale median (GSM), on the risk of stroke during CAS.

Methods and results: The Imaging in Carotid Angioplasty and Risk of Stroke (ICAROS) registry included 418 cases of CAS collected from 11 international centers. An echographic evaluation of carotid plaque with GSM measurement was made preprocedurally. The onset of neurological deficits during the procedure and the postprocedural period was recorded. The overall rate of neurological complications was 3.6%: minor strokes, 2.2%, and major stroke, 1.4%. There were 11 of 155 strokes (7.1%) in patients with GSM < or =25 and 4 of 263 (1.5%) in patients with GSM >25 (P=0.005). Patients with severe stenosis (> or =85%) had a higher rate of stroke (P=0.03). The effectiveness of brain protection devices was confirmed in those with GSM >25 (P=0.01) but not in those with GSM < or =25. Multivariate analysis revealed that GSM (OR, 7.11; P=0.002) and rate of stenosis (OR, 5.76; P=0.010) are independent predictors of stroke.

Conclusions: Carotid plaque echolucency, as measured by GSM < or =25, increases the risk of stroke in CAS. The inclusion of echolucency measured as GSM in the planning of any endovascular procedure of carotid lesions allows stratification of patients at different risks of complications in CAS.

PubMed Disclaimer

Publication types

MeSH terms