Identification of the epidural space: loss of resistance with air, lidocaine, or the combination of air and lidocaine
- PMID: 15281538
- DOI: 10.1213/01.ANE.0000120084.56136.15
Identification of the epidural space: loss of resistance with air, lidocaine, or the combination of air and lidocaine
Abstract
The ideal technique for identifying the epidural space remains unclear. Five-hundred-forty-seven women in labor who requested epidural analgesia were randomly allocated to three groups according to the technique by which the epidural space was identified: 1) loss-of-resistance with air (air; n = 180), 2) loss-of-resistance with lidocaine (lidocaine; n = 185), and 3) loss-of-resistance with both air and lidocaine (air-plus-lidocaine; n = 182). We assessed ease of epidural catheter insertion, characteristics of the blockade, quality of analgesia, and complications. The inability to thread the epidural catheter occurred in 16% of the air, 4% of the lidocaine, and 3% of the air-plus-lidocaine patients (P < 0.001). More patients from the air group had unblocked segments (6.6% versus 3.2% and 2.2%, respectively; P < 0.02). The incidence of accidental dural puncture was greater in the air group (1.7% versus 0% in the other two groups; P < 0.02). Pain scores, time to onset of analgesia, upper sensory level, motor blockade, and the incidence of hypotension, transient neurological deficits, postpartum urinary retention, and postdural puncture headache were comparable. Identification of the epidural space with air was more difficult and caused more dural punctures than with lidocaine or air plus lidocaine. Additionally, sequential use of air and lidocaine had no advantage over lidocaine alone.
Comment in
-
Identification of the epidural space.Anesth Analg. 2005 Apr;100(4):1218. doi: 10.1213/01.ANE.0000149013.28177.EE. Anesth Analg. 2005. PMID: 15781562 No abstract available.
References
-
- Scott DB. Identification of the epidural space: loss of resistance to air or saline? Reg Anesth 1997;22:1–2.
-
- Russell R. Loss of resistance to saline is better than air for obstetric epidurals. Int J Obstet Anesth 2001;10:302–6.
-
- Stride PC, Cooper GM. Dural taps revisited: a 20-year survey from Birmingham Maternity Hospital. Anaesthesia 1993;48:247–55.
-
- Gleeson CM, Reynolds F. Accidental dural puncture rates in UK obstetric practice. Int J Obstet Anesth 1998;7:242–6.
-
- Huffnagle SL, Norris MC, Arkoosh VA, et al. The influence of epidural needle bevel orientation on spread of sensory blockade in the laboring parturient. Anesth Analg 1998;87:326 –30.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources