Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2004;18(14):1621-8.
doi: 10.1002/rcm.1530.

Trace level quantification of deuterated 17beta-estradiol and estrone in ovariectomized mouse plasma and brain using liquid chromatography/tandem mass spectrometry following dansylation reaction

Affiliations

Trace level quantification of deuterated 17beta-estradiol and estrone in ovariectomized mouse plasma and brain using liquid chromatography/tandem mass spectrometry following dansylation reaction

Yuan-Qing Xia et al. Rapid Commun Mass Spectrom. 2004.

Abstract

A sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method coupled with dansylation was developed for the simultaneous quantification of exogenously administered deuterated 17beta-estradiol-d4 (E2-d4) and its metabolite, estrone-d4 (E1-d4), in mouse plasma and brain homogenates. The dansylation reaction was simple, fast, and sensitive, and a lower limit of quantification of 50 pg/mL was achieved by using 50 microL of mouse plasma. Interference from endogenous 17beta-estradiol and estrone in plasma and brain samples was minimized by the use of deuterated-E2 as well by utilizing ovariectomized (OVX) mice. The recovery of dansylated derivative exceeded 83% and the reaction was completed within approximately 3 min. The intra- and inter-day assay precision were better than 12.9% and assay accuracy ranged between 92-104% for E1-d4 and E2-d4 in plasma, respectively. The absorption of E2-d4 at both 1 and 3 mg/kg P.O. was rapid, reaching peak plasma concentrations (Cmax) at 5 min post-dose that was the earliest time point obtained, and were 1.1 and 13.8 ng/mL, respectively; the Cmax values for the estrone metabolite, E1-d4, were 1.1 and 43.2 ng/mL, respectively. The area-under-the-plasma-time curve (AUC(0-2 h)) values were determined to be 0.65 and 2.90 ng. h/mL for E2-d4 and 0.77 and 6.74 ng. h/mL for E1-d4, respectively, at 1 and 3 mg/kg. The mean brain-to-plasma ratio for E1-d4 and E2-d4 after P.O. administration of E2-d4 to the OVX mice at 1 and 3 mg/kg indicated that both E1-d4 and E2-d4 were present in the brain as well as in the circulation.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources