MR procedures: biologic effects, safety, and patient care
- PMID: 15284433
- DOI: 10.1148/radiol.2323030830
MR procedures: biologic effects, safety, and patient care
Abstract
The technology used for magnetic resonance (MR) procedures has evolved continuously during the past 20 years, yielding MR systems with stronger static magnetic fields, faster and stronger gradient magnetic fields, and more powerful radiofrequency transmission coils. Most reported cases of MR-related injuries and the few fatalities that have occurred have apparently been the result of failure to follow safety guidelines or of use of inappropriate or outdated information related to the safety aspects of biomedical implants and devices. To prevent accidents in the MR environment, therefore, it is necessary to revise information on biologic effects and safety according to changes that have occurred in MR technology and with regard to current guidelines for biomedical implants and devices. This review provides an overview of and update on MR biologic effects, discusses new or controversial MR safety topics and issues, presents evidence-based guidelines to ensure safety for patients and staff, and describes safety information for various implants and devices that have recently undergone evaluation.
Copyright RSNA, 2004
Comment in
-
Can intrauterine devices actually be considered safe at 3-T MR imaging?Radiology. 2005 May;235(2):709. doi: 10.1148/radiol.2352041850. Radiology. 2005. PMID: 15858109 No abstract available.
Similar articles
-
Magnetic resonance imaging and safety aspects.Toxicol Ind Health. 2011 May;27(4):307-13. doi: 10.1177/0748233710386413. Epub 2010 Nov 26. Toxicol Ind Health. 2011. PMID: 21112927 Review.
-
Magnetic resonance safety update 2002: implants and devices.J Magn Reson Imaging. 2002 Nov;16(5):485-96. doi: 10.1002/jmri.10196. J Magn Reson Imaging. 2002. PMID: 12412025 Review.
-
Safety issues and updates under MR environments.Eur J Radiol. 2017 Apr;89:7-13. doi: 10.1016/j.ejrad.2017.01.010. Epub 2017 Jan 21. Eur J Radiol. 2017. PMID: 28267552 Review.
-
The AAPM/RSNA physics tutorial for residents. MR imaging safety considerations. Radiological Society of North America.Radiographics. 1999 Nov-Dec;19(6):1641-51. doi: 10.1148/radiographics.19.6.g99no331641. Radiographics. 1999. PMID: 10555679 Review.
-
Injuries associated with MR imaging: survey of safety records and methods used to screen patients for metallic foreign bodies before imaging.AJR Am J Roentgenol. 1994 Jan;162(1):189-94. doi: 10.2214/ajr.162.1.8273663. AJR Am J Roentgenol. 1994. PMID: 8273663
Cited by
-
Uncertainty Quantification in SAR Induced by Ultra-High-Field MRI RF Coil via High-Dimensional Model Representation.Bioengineering (Basel). 2024 Jul 18;11(7):730. doi: 10.3390/bioengineering11070730. Bioengineering (Basel). 2024. PMID: 39061812 Free PMC article.
-
Implementation of a comprehensive MR safety course for medical students.J Magn Reson Imaging. 2015 Dec;42(6):1478-86. doi: 10.1002/jmri.24993. Epub 2015 Jul 14. J Magn Reson Imaging. 2015. PMID: 26172156 Free PMC article. Review.
-
Patient safety issues in magnetic resonance imaging: state of the art.Radiol Med. 2007 Jun;112(4):491-508. doi: 10.1007/s11547-007-0154-4. Epub 2007 Jun 11. Radiol Med. 2007. PMID: 17563855 Review. English, Italian.
-
MRI Compatibility: Automatic Brain Shunt Valve Recognition using Feature Engineering and Deep Convolutional Neural Networks.Sci Rep. 2018 Oct 30;8(1):16052. doi: 10.1038/s41598-018-34164-6. Sci Rep. 2018. PMID: 30375411 Free PMC article.
-
Magnetic resonance angiography: current status and future directions.J Cardiovasc Magn Reson. 2011 Mar 9;13(1):19. doi: 10.1186/1532-429X-13-19. J Cardiovasc Magn Reson. 2011. PMID: 21388544 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical