Purpose: To assess whether characterization of solid focal liver lesions could be improved by using ultrasonographic (US) contrast-specific modes after sulfur hexafluoride-filled microbubble contrast agent injection, as compared with lesion characterization achieved with preliminary baseline US.
Materials and methods: Four hundred fifty-two solid focal hepatic lesions that were considered indeterminate at baseline gray-scale and color Doppler US were examined after microbubble contrast agent injection performed by using low-acoustic-power contrast-specific modes during the arterial (10-40 seconds after injection), portal venous (50-90 seconds after injection), and late (100-300 seconds after injection) phases. Two readers independently and retrospectively reviewed baseline and contrast material-enhanced US scans and classified each depicted lesion as malignant or benign according to standard diagnostic criteria. Sensitivity, specificity, accuracy, and positive and negative predictive values and areas under the receiver operating characteristic curve (Az) were calculated by considering histologic analysis (317 patients) or contrast-enhanced helical computed tomography followed by serial US 3-6 months apart (135 patients) as the reference standards.
Results: Different contrast enhancement patterns were observed according to lesion characteristics. During the late phase, benign lesions were predominantly hyper- or isoechoic relative to the adjacent liver parenchyma, whereas malignant lesions were predominantly hypoechoic. Review of the contrast-enhanced US scans after baseline image review yielded significantly improved diagnostic performance (P <.05). Overall diagnostic accuracy was 49% before versus 85% after review of the contrast-enhanced scan for reader 1 and 51% before versus 88% after review of the contrast-enhanced scan for reader 2. Diagnostic confidence-that is, the Az-was 0.820 before versus 0.968 after review of the contrast-enhanced scan for reader 1 and 0.831 before versus 0.978 after review of the contrast-enhanced scan for reader 2.
Conclusion: The use of contrast-specific modes with a sulfur hexafluoride contrast agent led to improved characterization of solid focal liver lesions.
Copyright RSNA, 2004
Similar articles
-
Comparison of diagnostic performance of unenhanced vs SonoVue - enhanced ultrasonography in focal liver lesions characterization. The experience of three Italian centers.Radiol Med. 2004 Jul-Aug;108(1-2):71-81. Radiol Med. 2004. PMID: 15269691 Clinical Trial. English, Italian.
-
[Characterization of focal liver lesions with contrast-enhanced low MI real time ultrasound and SonoVue].Rofo. 2003 Jun;175(6):835-43. doi: 10.1055/s-2003-39923. Rofo. 2003. PMID: 12811698 German.
-
Differential patterns of contrast enhancement in different focal liver lesions after injection of the microbubble US contrast agent SonoVue.Radiol Med. 2004 Mar;107(3):155-65. Radiol Med. 2004. PMID: 15031681 English, Italian.
-
[Contrast-enhanced ultrasound in hepatic focal nodular hyperplasia].Rev Med Liege. 2012 Mar;67(3):113-7. Rev Med Liege. 2012. PMID: 22611826 Review. French.
-
Contrast-Enhanced Ultrasound of Focal Liver Lesions.AJR Am J Roentgenol. 2015 Jul;205(1):W56-66. doi: 10.2214/AJR.14.14203. AJR Am J Roentgenol. 2015. PMID: 26102419 Review.
Cited by
-
Current consensus and guidelines of contrast enhanced ultrasound for the characterization of focal liver lesions.Clin Mol Hepatol. 2013 Mar;19(1):1-16. doi: 10.3350/cmh.2013.19.1.1. Epub 2013 Mar 25. Clin Mol Hepatol. 2013. PMID: 23593604 Free PMC article. Review.
-
Impact of European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) guidelines on the use of contrast agents in liver ultrasound.Eur Radiol. 2006 Jul;16(7):1610-3. doi: 10.1007/s00330-005-0123-z. Epub 2006 Feb 21. Eur Radiol. 2006. PMID: 16491349
-
Intraoperative ultrasound in patients with hepatocellular carcinoma: from daily practice to future trends.Liver Cancer. 2013 Jan;2(1):16-24. doi: 10.1159/000346421. Liver Cancer. 2013. PMID: 24159592 Free PMC article. Review.
-
Diagnostic value of contrast-enhanced ultrasound in thyroid nodules with calcification.Kaohsiung J Med Sci. 2015 Mar;31(3):138-44. doi: 10.1016/j.kjms.2014.12.001. Epub 2015 Jan 17. Kaohsiung J Med Sci. 2015. PMID: 25744236 Free PMC article.
-
The impact of ultrasound contrast-enhanced fusion virtual navigation technology-guided microwave ablation (MWA) and standard MWA on the local tumor progression of hepatocellular carcinoma with unclear ultrasound images.Eur J Med Res. 2025 Jun 4;30(1):451. doi: 10.1186/s40001-025-02608-1. Eur J Med Res. 2025. PMID: 40468422 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical