Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2004 Aug;89(8):3687-93.
doi: 10.1210/jc.2003-032235.

Steroid profiling by tandem mass spectrometry improves the positive predictive value of newborn screening for congenital adrenal hyperplasia

Affiliations

Steroid profiling by tandem mass spectrometry improves the positive predictive value of newborn screening for congenital adrenal hyperplasia

Carla Z Minutti et al. J Clin Endocrinol Metab. 2004 Aug.

Abstract

Congenital adrenal hyperplasia (CAH) is primarily caused by 21-hydroxylase deficiency and leads to an accumulation of 17-hydroxyprogesterone and reduced cortisol levels. Newborn screening for CAH is traditionally based on measuring 17-hydroxyprogesterone by different immunoassays. Despite attempts to adjust cutoff levels for birth weight, gestational age, and stress factors, the positive predictive value for CAH screening remains less than 1%. To improve this situation, we developed a method using liquid chromatography-tandem mass spectrometry to measure 17-hydroxyprogesterone, androstenedione, and cortisol simultaneously in blood spots. A total of 1222 leftover blood spots from six different screening programs using different immunoassays (fluorescent immunoassay and ELISA) were reanalyzed in a blinded fashion by liquid chromatography-tandem mass spectrometry. Thirty-one samples were from babies with CAH, 190 had yielded false-positive results by immunoassay, and the remaining 1001 samples were from babies with normal screening results. Steroid profiling allowed for an elimination of 169 (89%) of the false-positive results and for an improvement of the positive predictive value from the reported 0.5 to 4.7%. Although this method is not suitable for mass screening due to the length of the analysis (12 min), it can be used as a second-tier test of blood spots with positive results for CAH by the conventional methods. This would prevent unnecessary blood draws, medical evaluations, and stress to families.

PubMed Disclaimer

Comment in

Similar articles

Cited by