A modeling investigation was performed to choose moderator material and size for creating optimal epithermal neutron beams for BNCT based on a proton accelerator and the (7)Li(p,n)(7)Be reaction as a neutrons source. An optimal configuration is suggested for the beam shaping assembly made from polytetrafluoroethylene and magnesium fluorine to be placed on high current IPPE proton accelerator KG-2.5. Results of calculation were experimentally tested and are in good agreement with measurements.
Similar articles
-
A neutron producing target for BINP accelerator-based neutron source.Appl Radiat Isot. 2009 Jul;67(7-8 Suppl):S282-4. doi: 10.1016/j.apradiso.2009.03.076. Epub 2009 Mar 27. Appl Radiat Isot. 2009. PMID: 19376729
-
A shielding design for an accelerator-based neutron source for boron neutron capture therapy.Appl Radiat Isot. 2004 Nov;61(5):1027-31. doi: 10.1016/j.apradiso.2004.05.038. Appl Radiat Isot. 2004. PMID: 15308187
-
The BSA modeling for the accelerator-based BNCT facility at INFN LNL for treating shallow skin melanoma.Appl Radiat Isot. 2009 Jul;67(7-8 Suppl):S274-7. doi: 10.1016/j.apradiso.2009.03.074. Epub 2009 Mar 27. Appl Radiat Isot. 2009. PMID: 19376724
-
Accelerator-based epithermal neutron sources for boron neutron capture therapy of brain tumors.J Neurooncol. 2003 Mar-Apr;62(1-2):19-31. doi: 10.1007/BF02699931. J Neurooncol. 2003. PMID: 12749700 Review.
-
[Development of BNCT based on research using accelerator based neutron source].Igaku Butsuri. 2012;32(3):104-10. Igaku Butsuri. 2012. PMID: 24592679 Review. Japanese. No abstract available.
Cited by
-
Feasibility study on the use of 230 MeV proton cyclotron in proton therapy centers as a spallation neutron source for BNCT.Rep Pract Oncol Radiother. 2019 Nov-Dec;24(6):644-653. doi: 10.1016/j.rpor.2019.10.005. Epub 2019 Oct 30. Rep Pract Oncol Radiother. 2019. PMID: 31719802 Free PMC article.
-
Optimization of the photoneutron target geometry for e-accelerator based BNCT.Electron Physician. 2017 Jun 25;9(6):4590-4596. doi: 10.19082/4590. eCollection 2017 Jun. Electron Physician. 2017. PMID: 28848635 Free PMC article.
-
Optimized beam shaping assembly for a 2.1-MeV proton-accelerator-based neutron source for boron neutron capture therapy.Sci Rep. 2021 Apr 7;11(1):7576. doi: 10.1038/s41598-021-87305-9. Sci Rep. 2021. PMID: 33828211 Free PMC article.
-
An Integrated Monte Carlo Model for Heterogeneous Glioblastoma Treated with Boron Neutron Capture Therapy.Cancers (Basel). 2023 Mar 1;15(5):1550. doi: 10.3390/cancers15051550. Cancers (Basel). 2023. PMID: 36900341 Free PMC article.
-
Facility optimization to improve activation rate distributions during IVNAA.J Radiat Res. 2013 May;54(3):515-31. doi: 10.1093/jrr/rrs124. Epub 2013 Feb 5. J Radiat Res. 2013. PMID: 23386375 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources