Myocardial distribution of indium-111-antimyosin Fab and technetium-99m-sestamibi in experimental nontransmural infarction
- PMID: 1531070
Myocardial distribution of indium-111-antimyosin Fab and technetium-99m-sestamibi in experimental nontransmural infarction
Abstract
Early revascularization in acute myocardial infarction results in normal, necrotic and partially damaged and partially salvaged ("intermediate") myocardium. By combining a perfusion tracer and a marker for myocardial injury, we attempted to differentiate between these three types of cardiac tissue. The LAD was occluded in nine pigs for 45 min and then reperfused. After 48 and 72 hr, 74 MBq 111In-antimyosin Fab and 740 MBq 99mTc-sestamibi, respectively, were injected intravenously. Normally perfused myocardium was labeled with fluorescein and the heart excised. Three to four slices were cut from the apex. Tetrazolium staining revealed the zone of necrosis. Tracer distribution on double-nuclide scintigrams of the slices also reflected the three different myocardial zones. Guided by fluorescence and macrohistochemistry, tissue samples were excised from each zone. In relation to normal myocardium, mean activity in the intermediate zone was 0.82 +/- 0.20 for 99mTc-sestamibi and 2.84 +/- 1.31 for 111In-antimyosin Fab. Activity in necrotic myocardium was 0.30 +/- 0.19 and 3.95 +/- 2.47, respectively. These results show that 111In-antimyosin Fab fragments not only accumulate in necrotic but also in intermediate myocardium. Therefore, an overestimation of infarct size may occur if 111In-antimyosin Fab fragments are used alone without a perfusion tracer.
Comment in
-
Transmural uptake of perfusion tracers and infarct-specific tracers.J Nucl Med. 1992 Feb;33(2):229-30. J Nucl Med. 1992. PMID: 1531071 No abstract available.
Similar articles
-
Transmural uptake of perfusion tracers and infarct-specific tracers.J Nucl Med. 1992 Feb;33(2):229-30. J Nucl Med. 1992. PMID: 1531071 No abstract available.
-
[Simultaneous double nucleotide scintigraphy with indium 111 antimyosin Fab and technetium sestamibi for evaluation of myocardial viability after experimental and clinical infarct].Z Kardiol. 1996 Jun;85(6):388-94. Z Kardiol. 1996. PMID: 8767363 German.
-
Myocardial damage delineated by indium-111 antimyosin Fab and technetium-99m pyrophosphate.J Nucl Med. 1987 Jan;28(1):76-82. J Nucl Med. 1987. PMID: 3025386
-
Immunoscintigraphy with 111In antimyosin Fab.Nucl Med Commun. 1990 Nov;11(11):727-35. doi: 10.1097/00006231-199011000-00002. Nucl Med Commun. 1990. PMID: 2277688 Review.
-
Detection of myocardial necrosis and inflammation by nuclear cardiac imaging.Cardiol Clin. 1994 May;12(2):289-302. Cardiol Clin. 1994. PMID: 8033178 Review.
Cited by
-
99mTc-sestamibi kinetics predict myocardial viability in a perfused rat heart model.Eur J Nucl Med Mol Imaging. 2008 Mar;35(3):570-8. doi: 10.1007/s00259-007-0549-4. Epub 2007 Oct 19. Eur J Nucl Med Mol Imaging. 2008. PMID: 17952434 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous