. 2004 Aug;9(4):173-7.
doi: 10.1097/00126097-200408000-00001.

Temporal stability of twenty-four-hour ambulatory hemodynamic bioimpedance measures in African American adolescents

Affiliations

Temporal stability of twenty-four-hour ambulatory hemodynamic bioimpedance measures in African American adolescents

Vernon A Barnes et al. Blood Press Monit. 2004 Aug.

Abstract

Background: The reliability of ambulatory impedance cardiography has not been evaluated.

Objective: The purpose of this study was to determine the reproducibility of daytime and night-time ambulatory bioimpedance-derived measures of hemodynamic function in youth.

Methods: Thirty-five African American adolescents (ages 16.2+/-1.4 years, 14 girls, 21 boys) with high normal systolic resting blood pressure (BP) were evaluated twice, separated by a 2-month interval. Measures were collected using the AIM-8-V3 Wearable Cardiac Performance Monitor (Bio-impedance Technology, Inc., Chapel Hill, North Carolina, USA) and the Spacelabs ambulatory BP monitor 90207 (Spacelabs Inc., Redmond, Washington, USA) from 0600 h to midnight every 20 min and from midnight to 0600 h every 30 min in the natural environment.

Results: There were no significantly different means (P>0.15) between the two visits for daytime ambulatory heart rate (HR, r = 0.81), stroke volume (SV, r = 0.54), cardiac output (CO, r = 0.56), pre-ejection period (PEP, r = 0.59), left ventricular ejection time (LVET, r = 0.74), Heather Index (HI, r = 0.79), systolic BP (SBP, r = 0.79), diastolic BP (DBP, r = 0.66), mean arterial pressure (MAP, r = 0.65) and total peripheral resistance (TPR, r = 0.47). Overall means for night-time ambulatory HR (r = 0.76), SV (r = 0.49), CO (r = 0.45), LVET (r = 0.43), HI (r = 0.82), SBP (r = 0.65), DBP (r = 0.62), MAP (r = 0.63) and TPR (r = 0.20) were not significantly different between visits (P > 0.06). Mean differences (P < 0.01) were observed for PEP (r = 0.57).

Conclusions: The findings demonstrate that across 2 months in youth daytime and night-time ambulatory bioimpedance-derived measures of HR, HI, SBP, DBP and MAP are highly repeatable and SV, CO, PEP and LVET are moderately repeatable. This methodology should prove useful in cardiovascular research and clinical care.

PubMed Disclaimer

Conflict of interest statement

Conflict of interest: None

Similar articles

Cited by

References

    1. Allen MT, Matthews KA. Hemodynamic responses to laboratory stressors in children and adolescents: the influences of age, race and gender. Psychophysiology. 1997;34:329–339. - PubMed
    1. Braden DS, Leatherbury L, Treiber FA, Strong WB. Noninvasive assessment of cardiac output in children using impedance cardiography. Am Heart J. 1990;120:1166–1172. - PubMed
    1. McGrath JJ, O’Brien WH. Pediatric impedance cardiography: Temporal stability and intertask consistency. Psychophysiology. 2001;38:479–484. - PubMed
    1. Zhang YJ, Qu MH, Webster JG, Tompkins WJ, Ward BA, Bassett DRJ. Cardiac output monitoring by impedance cardiography during treadmill exercise. IEEE Trans Biomed Eng. 1986;33:1037–1042. - PubMed
    1. Zhang Y, Qu MH, Webster JG, Tompkins WJ. Impedance cardiography for ambulatory subjects. Frontiers of engineering and computing in health care; Proceedings of the Seventh Annual Conference of the IEEE/Engineering in Medicine and Biology Society; 1985; New York. IEEE; 1985. pp. 764–769.

Publication types