[Nyctohemeral variations in intraocular pressure]
- PMID: 15314571
[Nyctohemeral variations in intraocular pressure]
Abstract
Intraocular pressure (IOP) varies and depends on many factors. These variations throughout the nycthemeron (the full 24-h period of a night and a day) are the most interesting to study. With the current techniques, it is impossible to measure continuously without waking the subject. Therefore, IOP must be measured hourly over 24 h with a portable tonometer, which provides short measurements in any posture, without requiring the subjects to rise during the night. Intraocular pressure depends on a nyctohemeral rhythm and in healthy subjects is higher at night than during the day, with a nocturnal peak value (acrophase). In the same normal individual, several 24-h measurements are identical. Each individual has his own 24-h IOP pattern. In glaucoma patients, however, the 24-h IOP rhythm was shown to be reversed, with values higher during the day (a midday peak in IOP) than during the night. The time course of the nyctohemeral curve of intraocular pressure is considered to play a role in the prognosis of glaucoma and can serve to classify the type of glaucoma (POAG, NTG). Lowering IOP is still the only option that is available for treating patients with glaucoma. Variations encountered in the individual's nyctohemeral IOP pattern must be taken into consideration to provide the most effective treatment.
Copyright 2004 Masson
Similar articles
-
Twenty-four hour (Nyctohemeral) rhythm of intraocular pressure and ocular perfusion pressure in normal-tension glaucoma.Invest Ophthalmol Vis Sci. 2010 Feb;51(2):882-9. doi: 10.1167/iovs.09-3668. Epub 2009 Aug 13. Invest Ophthalmol Vis Sci. 2010. PMID: 19684006
-
Pathophysiology of glaucoma and continuous measurements of intraocular pressure.Mol Cell Biomech. 2009 Mar;6(1):57-69. Mol Cell Biomech. 2009. PMID: 19382536 Review.
-
[Diurnal variation curve of intraocular pressure and ocular pulse amplitude with dynamic contour tonometer in primary open-angle glaucoma and normal tension glaucoma patients].Zhonghua Yi Xue Za Zhi. 2006 Dec 26;86(48):3401-4. Zhonghua Yi Xue Za Zhi. 2006. PMID: 17313852 Chinese.
-
24-h monitoring devices and nyctohemeral rhythms of intraocular pressure.Prog Retin Eye Res. 2016 Nov;55:108-148. doi: 10.1016/j.preteyeres.2016.07.002. Epub 2016 Jul 28. Prog Retin Eye Res. 2016. PMID: 27477112 Review.
-
24-hour intraocular pressure rhythm in young healthy subjects evaluated with continuous monitoring using a contact lens sensor.JAMA Ophthalmol. 2013 Dec;131(12):1507-16. doi: 10.1001/jamaophthalmol.2013.5297. JAMA Ophthalmol. 2013. PMID: 24158696
Cited by
-
Timolol 0.1% in Glaucomatous Patients: Efficacy, Tolerance, and Quality of Life.J Ophthalmol. 2019 May 2;2019:4146124. doi: 10.1155/2019/4146124. eCollection 2019. J Ophthalmol. 2019. PMID: 31191995 Free PMC article. Review.
-
Prevalence and risk factors of primary open-angle glaucoma in a city of Eastern China: a population-based study in Pudong New District, Shanghai.BMC Ophthalmol. 2015 Oct 13;15:134. doi: 10.1186/s12886-015-0124-x. BMC Ophthalmol. 2015. PMID: 26462564 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical