Miniaturized multiplex label-free electronic chip for rapid nucleic acid analysis based on carbon nanotube nanoelectrode arrays
- PMID: 15319319
- DOI: 10.1373/clinchem.2004.036285
Miniaturized multiplex label-free electronic chip for rapid nucleic acid analysis based on carbon nanotube nanoelectrode arrays
Abstract
Background: Reducing cost and time is the major concern in clinical diagnostics, particularly in molecular diagnostics. Miniaturization technologies have been recognized as promising solutions to provide low-cost microchips for diagnostics. With the recent advancement in nanotechnologies, it is possible to further improve detection sensitivity and simplify sample preparation by incorporating nanoscale elements in diagnostics devices. A fusion of micro- and nanotechnologies with biology has great potential for the development of low-cost disposable chips for rapid molecular analysis that can be carried out with simple handheld devices.
Approach: Vertically aligned multiwalled carbon nanotubes (MWNTs) are fabricated on predeposited microelectrode pads and encapsulated in SiO2 dielectrics with only the very end exposed at the surface to form an inlaid nanoelectrode array (NEA). The NEA is used to collect the electrochemical signal associated with the target molecules binding to the probe molecules, which are covalently attached to the end of the MWNTs.
Content: A 3 x 3 microelectrode array is presented to demonstrate the miniaturization and multiplexing capability. A randomly distributed MWNT NEA is fabricated on each microelectrode pad. Selective functionalization of the MWNT end with a specific oligonucleotide probe and passivation of the SiO2 surface with ethylene glycol moieties are discussed. Ru(bpy)2+ -mediator-amplified guanine oxidation is used to directly measure the electrochemical signal associated with target molecules.
Summary: The discussed MWNT NEAs have ultrahigh sensitivity in direct electrochemical detection of guanine bases in the nucleic acid target. Fewer than approximately 1000 target nucleic acid molecules can be measured with a single microelectrode pad of approximately 20 x 20 microm2, which approaches the detection limit of laser scanners in fluorescence-based DNA microarray techniques. MWNT NEAs can be easily integrated with microelectronic circuitry and microfluidics for development of a fully automated system for rapid molecular analysis with minimum cost.
Similar articles
-
Ultrasensitive label-free DNA analysis using an electronic chip based on carbon nanotube nanoelectrode arrays.Nanotechnology. 2003 Dec;14(12):1239-45. doi: 10.1088/0957-4484/14/12/001. Epub 2003 Oct 17. Nanotechnology. 2003. PMID: 21444977
-
Arrays of carbon nanofibers as a platform for biosensing at the molecular level and for tissue engineering and implantation.Biomed Mater Eng. 2009;19(1):35-43. doi: 10.3233/BME-2009-0561. Biomed Mater Eng. 2009. PMID: 19458444
-
Wafer-scale fabrication of patterned carbon nanofiber nanoelectrode arrays: a route for development of multiplexed, ultrasensitive disposable biosensors.Biosens Bioelectron. 2009 May 15;24(9):2818-24. doi: 10.1016/j.bios.2009.02.009. Epub 2009 Feb 21. Biosens Bioelectron. 2009. PMID: 19303281
-
Active microelectronic array system for DNA hybridization, genotyping and pharmacogenomic applications.Psychiatr Genet. 2002 Dec;12(4):181-92. doi: 10.1097/00041444-200212000-00001. Psychiatr Genet. 2002. PMID: 12454523 Review.
-
Integration of electrochemistry in micro-total analysis systems for biochemical assays: recent developments.Talanta. 2009 Nov 15;80(1):8-18. doi: 10.1016/j.talanta.2009.06.039. Epub 2009 Jun 24. Talanta. 2009. PMID: 19782186 Review.
Cited by
-
Detection of Alpha-Fetoprotein Using Aptamer-Based Sensors.Biosensors (Basel). 2022 Sep 21;12(10):780. doi: 10.3390/bios12100780. Biosensors (Basel). 2022. PMID: 36290918 Free PMC article. Review.
-
Assembling Amperometric Biosensors for Clinical Diagnostics.Sensors (Basel). 2008 Feb 27;8(3):1366-1399. doi: 10.3390/s8031366. Sensors (Basel). 2008. PMID: 27879771 Free PMC article.
-
Label-free technologies for quantitative multiparameter biological analysis.Anal Bioanal Chem. 2009 May;394(1):121-35. doi: 10.1007/s00216-009-2637-8. Epub 2009 Feb 17. Anal Bioanal Chem. 2009. PMID: 19221722 Free PMC article. Review.
-
Review of transducer principles for label-free biomolecular interaction analysis.Biosensors (Basel). 2011 Jul 1;1(3):70-92. doi: 10.3390/bios1030070. Biosensors (Basel). 2011. PMID: 25586921 Free PMC article. Review.
-
Simultaneous, multiplex quantification of protease activities using a gold microelectrode array.Biosens Bioelectron. 2020 Oct 1;165:112330. doi: 10.1016/j.bios.2020.112330. Epub 2020 May 30. Biosens Bioelectron. 2020. PMID: 32729476 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources