Introduction to Laplacian montages
- PMID: 15328706
Introduction to Laplacian montages
Abstract
Digital EEG systems allow for the creation of specialized montages not commonly available previously with analog equipment. Montages that employ the principles of local average reference techniques utilize a subset of spatially separated electrodes to produce a synthetic reference that will aid in localization. By employing these techniques, focal discharges can be visually enhanced and properly localized. The Laplacian transform is an example of a local average reference and the principles and construction of this montage are described here in brief detail. Though the montage is not suited for all situations, integration into existing lab protocols will enable technologists to provide alternative views when required in ambiguous and difficult to interpret recordings.
Similar articles
-
Electrode position scaling in realistic laplacian computation.IEEE Trans Biomed Eng. 2008 Sep;55(9):2314-6. doi: 10.1109/TBME.2008.921168. IEEE Trans Biomed Eng. 2008. PMID: 18713701
-
Tri-polar concentric ring electrode development for laplacian electroencephalography.IEEE Trans Biomed Eng. 2006 May;53(5):926-33. doi: 10.1109/TBME.2005.863887. IEEE Trans Biomed Eng. 2006. PMID: 16686415 Clinical Trial.
-
Electroencephalography in neonatal seizures: comparison of a reduced and a full 10/20 montage.Pediatr Neurol. 2005 Mar;32(3):155-61. doi: 10.1016/j.pediatrneurol.2004.09.014. Pediatr Neurol. 2005. PMID: 15730894
-
Cerebral source localization paradigms: spatiotemporal source modeling.Brain Cogn. 1995 Apr;27(3):256-87. doi: 10.1006/brcg.1995.1023. Brain Cogn. 1995. PMID: 7626277 Review.
-
The advantages of digital over analog recording techniques.Electroencephalogr Clin Neurophysiol. 1998 Feb;106(2):113-7. Electroencephalogr Clin Neurophysiol. 1998. PMID: 9741771 Review.
Cited by
-
Computational Pipeline for NIRS-EEG Joint Imaging of tDCS-Evoked Cerebral Responses-An Application in Ischemic Stroke.Front Neurosci. 2016 Jun 20;10:261. doi: 10.3389/fnins.2016.00261. eCollection 2016. Front Neurosci. 2016. PMID: 27378836 Free PMC article.
-
The Influence of EEG References on the Analysis of Spatio-Temporal Interrelation Patterns.Front Neurosci. 2019 Sep 12;13:941. doi: 10.3389/fnins.2019.00941. eCollection 2019. Front Neurosci. 2019. PMID: 31572110 Free PMC article.
-
EEG response varies with lesion location in patients with chronic stroke.J Neuroeng Rehabil. 2016 Mar 2;13:21. doi: 10.1186/s12984-016-0120-2. J Neuroeng Rehabil. 2016. PMID: 26935230 Free PMC article.
-
Montages for Noninvasive EEG Recording.J Clin Neurophysiol. 2019 Sep;36(5):330-336. doi: 10.1097/WNP.0000000000000546. J Clin Neurophysiol. 2019. PMID: 31490450 Free PMC article. Review.
-
EEG Phase Can Be Predicted with Similar Accuracy across Cognitive States after Accounting for Power and Signal-to-Noise Ratio.eNeuro. 2023 Sep 5;10(9):ENEURO.0050-23.2023. doi: 10.1523/ENEURO.0050-23.2023. Print 2023 Sep. eNeuro. 2023. PMID: 37558464 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Miscellaneous