[A new custom-made artificial articular cartilage of femoral condyle based on rapid prototyping technique: a case report]

[Article in Chinese]
Affiliations
  • PMID: 15329237
Case Reports

[A new custom-made artificial articular cartilage of femoral condyle based on rapid prototyping technique: a case report]

[Article in Chinese]
Zhen Wang et al. Zhonghua Wai Ke Za Zhi. .

Abstract

Objective: To design and manufacture a new custom-made artificial articular cartilage of femoral condyle based on rapid prototyping technique and explore a method to solve the necroses of allocartilage in hemi joint allotransplantation.

Methods: Design the new custom-made artificial articular cartilage of femoral condyle. The allograft and the patient distal femurs were scanned with Picker 6000 spiral computed tomography (CT) with 1.0 slice thickness and pitch of 1.5, reconstructed the distal femurs in Voxel Q image workstation with volume rendering technique. Then downloaded the transaxial 2D image data to personal computer at 0.1 mm interval and converted it into 2D digitized contour data by using image processing software developed by our team. The 3D wire frame and solid images of femoral condyle could be reconstructed when the 2D digitized contour data were input into image processing software Surfacer 9.0 (Imageware Company, USA). Subsequently based on the clinical experience and the need of design, the 3D contour image of articular cartilage was extracted from the surrounding. Based on the extracted 3D contour image, the computer-aided design (CAD) of the custom-made artificial articular cartilage was accomplished in Surfacer software, converted the CAD model into RP data format. Standard triangularization language, imported into the LPS600 rapid prototyping machine (Hengtong Company, Xi'an Jiaotong University, China), and the resin prototype was achieved. Then the resin model was used as a positive mould to build up a silica gel negative mould, the negative mould was sent to the factory to manufacture Ti-6Al-4V alloy articular cartilage through ordinary mould-melted founding process. Finally, the whole metal cartilage was completed after melting two special cages on it. A patient was selected to clinical applying.

Results: A new custom-made artificial articular cartilage of femoral condyle was made. It was press-fit well to the subchondral bone of the allograft bone. The patient's one and half year follow-up result was excellent.

Conclusions: We design and manufacture a new custom-made artificial articular cartilage of femoral condyle based on rapid prototyping technique. The result shows that the manufacturing process has the advantage of rapidness and precision that are very important for individualized artificial implant manufacturing. The artificial articular cartilage is press-fit well and could be a good idea to solve the necroses of allocartilage in hemijoint allotransplantation.