[Estimation of destruction of necrotic myocardium with serial PYP SPECT images and serum myosin light chain I level]
- PMID: 1532996
[Estimation of destruction of necrotic myocardium with serial PYP SPECT images and serum myosin light chain I level]
Abstract
PYP SPECT images were underwent in 15 patients with acute myocardial infarction 2-5 times in three weeks. PYP SPECT images were reconstructed as to include both vertebral images and myocardial images. Quantitative estimation of PYP images was performed by the ratio of maximal PYP myocardial uptake to maximal PYP vertebral uptake in the central sagittal images (%PYP). Disappearance of PYP images was defined as the day, when %PYP reached 50%. Normalization of serum myosin light chain I (LCI) level was defined as the day, when LCI level reached 2.5 ng/ml. %PYP decreased continuously and maximal PYP point remained at the same area. Shape of PYP images varied and diminished. In case of anterior wall infarction apical PYP uptake persisted longer than basal uptake. In case of inferior wall infarction basal PYP uptake persisted longer than apical uptake. The mean period from onset to the disappearance of PYP images was 9 +/- 3 days. Pattern of serial serum MB level was simple, however corresponding pattern of serial serum LCI level showed various types. The mean period from onset to the peak level was 4.1 +/- 1 day. Normalization of LCI level was 9.3 +/- 2.9 days. It showed that process of destruction of necrotic myocardium vary in each case. Weak relation was noted between disappearance of PYP images (DAY-PYP) and normalization of LCI level (DAY-LCI). DAY-PYP = 4.4 +/- 0.46 DAY-LCI (n = 13, r = 0.4). Quantitative PYP images were useful for detecting ongoing necrotic myocardium and serum LCI level was useful for estimating destruction of necrotic myocardium.2+ level were useful to study the process of destruction of necrotic myocardium.
Similar articles
-
Circulating myosin light chain I levels after coronary reperfusion: a comparison with myocardial necrosis evaluated from single photon emission computed tomography with pyrophosphate.Ann Nucl Med. 1992 Feb;6(1):43-9. doi: 10.1007/BF03164641. Ann Nucl Med. 1992. PMID: 1387796
-
[Clinical usefulness of 201Tl/99mTc-PYP dual myocardial quantitative gated SPECT program using low-dose dobutamine loading in assessment of myocardial viability in patient with acute myocardial infarction--a case report].Kaku Igaku. 2006 May;43(2):85-91. Kaku Igaku. 2006. PMID: 16838664 Japanese.
-
[Interesting PYP, Tl-201, MIBG and AM myocardial SPECT images in a patient under successful reperfusion therapy].Kaku Igaku. 1991 Sep;28(9):1099-103. Kaku Igaku. 1991. PMID: 1837571 Japanese.
-
[201Tl, 99mTc-PYP dual SPECT].Nihon Rinsho. 1994 Jul;52 Suppl(Pt 1):579-85. Nihon Rinsho. 1994. PMID: 12436585 Review. Japanese. No abstract available.
-
[201Tl, 99mTc-PYP dual SPECT].Nihon Rinsho. 2003 Apr;61 Suppl 4:347-52. Nihon Rinsho. 2003. PMID: 12734996 Review. Japanese. No abstract available.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous