Effects of temperature and outdoor air supply rate on the performance of call center operators in the tropics
- PMID: 15330779
- DOI: 10.1111/j.1600-0668.2004.00280.x
Effects of temperature and outdoor air supply rate on the performance of call center operators in the tropics
Abstract
A study was performed in a call center that provides billing inquiry services using a 2 x 2 balanced experimental plan for nine consecutive weeks. Two independent variables, temperature and outdoor air supply rate, were combined and introduced to the occupants in a blind intervention approach. The temperature set-points were fixed at 22.5 degrees C and 24.5 degrees C, and outdoor air supply rate at 5 l /s/p and 10 l/s/p. Temperature and outdoor air supply rate had significant interaction effects on worker's talk time (P < 0.001), which means that the effects of temperature on talk time performance were not independent of the effects of outdoor air supply rate or the opposite. Talk time was reduced significantly when the outdoor air supply rate was increased from 5 l /s/p to 10 l/s/p at 24.5 degrees C (P < 0.01); this may be associated with the significant reduction in a principal component factor which includes intensity of dryness, aching eyes and nose-related symptoms (P < 0.01). Decreasing the temperature from 24.5 degrees C to 22.5 degrees C at 10 l /s/p significantly increased talk time (P < 0.01). Analysis of the principal component factor based on the neurobehavioral symptoms also revealed that temperature reduction led to an increased mean factor score of these symptoms (P < 0.04).
Practical implications: For moderately complex office work which involves manipulation dexterity such as a call center operation where call operators interact with computer-based information systems, tropically acclimatized workers' performance could be improved by increasing the outdoor air supply rate from 5 l/s/p to 10 l/s/p if the temperature is to be maintained at the higher band of the thermal comfort range, around 24.5 degrees C. At a low ventilation rate (5 l/s/p), decreasing the temperature from 24.5 degrees C to 22.5 degrees C (which is a commonly adopted set-point in tropical office buildings) also leads to improvement of talk time performance. The magnitude of talk time improvement was greater by more than four times when the strategy to increase the outdoor air supply rate was implemented at a lower range of outdoor air supply rate (5-10 l /s/p) as compared to the higher range (9.8-22.7 l/s/p).
Similar articles
-
The performance and subjective responses of call-center operators with new and used supply air filters at two outdoor air supply rates.Indoor Air. 2004;14 Suppl 8:7-16. doi: 10.1111/j.1600-0668.2004.00304.x. Indoor Air. 2004. PMID: 15663456 Clinical Trial.
-
Impact of indoor air temperature and humidity in an office on perceived air quality, SBS symptoms and performance.Indoor Air. 2004;14 Suppl 7:74-81. doi: 10.1111/j.1600-0668.2004.00276.x. Indoor Air. 2004. PMID: 15330775 Clinical Trial.
-
The effects of indoor air quality on performance and productivity.Indoor Air. 2004;14 Suppl 7:92-101. doi: 10.1111/j.1600-0668.2004.00278.x. Indoor Air. 2004. PMID: 15330777
-
Summary of human responses to ventilation.Indoor Air. 2004;14 Suppl 7:102-18. doi: 10.1111/j.1600-0668.2004.00279.x. Indoor Air. 2004. PMID: 15330778 Review.
-
Personalized ventilation.Indoor Air. 2004;14 Suppl 7:157-67. doi: 10.1111/j.1600-0668.2004.00284.x. Indoor Air. 2004. PMID: 15330783 Review.
Cited by
-
Energy and cost associated with ventilating office buildings in a tropical climate.PLoS One. 2015 Mar 30;10(3):e0122310. doi: 10.1371/journal.pone.0122310. eCollection 2015. PLoS One. 2015. PMID: 25822504 Free PMC article.
-
Motivational decline and proactive response under thermal environmental stress are related to emotion- and problem-focused coping, respectively: Questionnaire construction and fMRI study.Front Behav Neurosci. 2023 Apr 12;17:1143450. doi: 10.3389/fnbeh.2023.1143450. eCollection 2023. Front Behav Neurosci. 2023. PMID: 37122493 Free PMC article.
-
Impact of Indoor Physical Environment on Learning Efficiency in Different Types of Tasks: A 3 × 4 × 3 Full Factorial Design Analysis.Int J Environ Res Public Health. 2018 Jun 13;15(6):1256. doi: 10.3390/ijerph15061256. Int J Environ Res Public Health. 2018. PMID: 29899260 Free PMC article.
-
Associations between indoor air exposures and cognitive test scores among university students in classrooms with increased ventilation rates for COVID-19 risk management.J Expo Sci Environ Epidemiol. 2025 Jul;35(4):661-671. doi: 10.1038/s41370-025-00770-6. Epub 2025 Apr 9. J Expo Sci Environ Epidemiol. 2025. PMID: 40204887
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous