Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2004 Sep;99(9):1684-9.
doi: 10.1111/j.1572-0241.2004.30347.x.

Endoscopic retrograde cholangiopancreatography, intraductal ultrasonography, and magnetic resonance cholangiopancreatography in bile duct strictures: a prospective comparison of imaging diagnostics with histopathological correlation

Affiliations
Comparative Study

Endoscopic retrograde cholangiopancreatography, intraductal ultrasonography, and magnetic resonance cholangiopancreatography in bile duct strictures: a prospective comparison of imaging diagnostics with histopathological correlation

Dirk Domagk et al. Am J Gastroenterol. 2004 Sep.

Abstract

Objectives: A variety of imaging techniques are available to diagnose bile duct strictures; the most effective imaging technique, however, has not been established yet. In the present study, we compared the impact of endoscopic retrograde cholangiopancreatography (ERCP), intraductal ultrasonography (IDUS), and magnetic resonance cholangiopancreatography (MRCP) with regard to diagnosing bile duct strictures.

Methods: We prospectively examined 33 patients with jaundice due to bile duct strictures by ERCP plus IDUS and MRCP. The objectives were to assess diagnostic quality of imaging, complete presentation of the bile duct, and differentiation of malignant from benign lesions. Surgical and histopathological correlations, which were used as the gold standard, were available in all cases since all included patients underwent laparotomy.

Results: Diagnostic image quality for ERCP was 88% and 76% for MRCP (p > 0.05). Comparing ERCP and MRCP, complete presentation of the biliary tract was achieved in 94% and 82%, respectively (p > 0.05). ERCP and MRCP allowed correct differentiation of malignant from benign lesions in 76% and 58% (p= 0.057), respectively. By supplementing ERCP with IDUS, the accuracy of correct differentiation of malignant from benign lesions increased significantly to 88% (p= 0.0047).

Conclusions: Comparing ERCP with MRCP, we found adequate presentation of bile duct strictures in high imaging quality for both techniques. ERCP supplemented by IDUS gives more reliable and precise information about differentiation of malignant and benign lesions than MRCP alone without additional imaging sequences.

PubMed Disclaimer

Comment in

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources