Atrial fibrillatory wave characteristics on surface electrogram: ECG to ECG repeatability over twenty-four hours in clinically stable patients
- PMID: 15333085
- DOI: 10.1046/j.1540-8167.2004.03577.x
Atrial fibrillatory wave characteristics on surface electrogram: ECG to ECG repeatability over twenty-four hours in clinically stable patients
Abstract
Introduction: Fibrillatory waves on the surface ECG have been scrutinized to allow inferences about underlying mechanisms and pathophysiology, based on the premise that fibrillatory waves do not vary "randomly" but provide a consistent reflection of the underlying state of the atria in an individual patient. This premise is untested.
Methods and results: Ten standard ECGs were recorded over a 24-hour period in each of 20 clinically stable inpatients with atrial fibrillation. After QRS-T cancellation, the remainder fibrillatory waves were analyzed. Interpatient versus intrapatient differences in fibrillatory wave characteristics were evaluated by analysis of variance (ANOVA). The fibrillatory wave peak-to-peak amplitude of all the patients ranged from 0.06 to 0.35 mV, whereas 1 SD of the amplitude for each patient ranged from 0.004 to 0.053 mV. Short-term peak frequencies of all the patients ranged from 4.6 to 8.0 Hz, whereas 1 SD for each patient varied from 0.2 to 0.5 Hz. For these and all other parameters tested, interpatient differences were significantly greater compared to intrapatient differences (P < 0.0001).
Conclusion: Fibrillatory wave characteristics are repeatable from ECG to ECG over 24 hours for clinically stable patients, whereas substantial differences are present between patients. Further study of the relationship of such characteristics to pathophysiology and management decisions is valid and warranted.
Comment in
-
Is analysis of fibrillatory waves useful for treatment of atrial fibrillation?J Cardiovasc Electrophysiol. 2004 Aug;15(8):918-9. doi: 10.1046/j.1540-8167.2004.04274.x. J Cardiovasc Electrophysiol. 2004. PMID: 15333086 No abstract available.
Similar articles
-
Electrocardiographic characteristics of fibrillatory waves in new-onset atrial fibrillation.Europace. 2007 Aug;9(8):638-42. doi: 10.1093/europace/eum074. Epub 2007 Apr 30. Europace. 2007. PMID: 17470676
-
Limitations of Dower's inverse transform for the study of atrial loops during atrial fibrillation.Pacing Clin Electrophysiol. 2009 Aug;32(8):972-80. doi: 10.1111/j.1540-8159.2009.02426.x. Pacing Clin Electrophysiol. 2009. PMID: 19659614
-
Relationship between pattern of occurrence of atrial fibrillation and surface electrocardiographic fibrillatory wave characteristics.Heart Rhythm. 2004 Dec;1(6):656-63. doi: 10.1016/j.hrthm.2004.09.010. Heart Rhythm. 2004. PMID: 15851236
-
Analysis of surface electrocardiograms in atrial fibrillation: techniques, research, and clinical applications.Europace. 2006 Nov;8(11):911-26. doi: 10.1093/europace/eul113. Europace. 2006. PMID: 17043067 Review.
-
The ECG as a tool to determine atrial fibrillation complexity.Heart. 2014 Jul;100(14):1077-84. doi: 10.1136/heartjnl-2013-305149. Epub 2014 May 16. Heart. 2014. PMID: 24837984 Review.
Cited by
-
Panoramic electrophysiological mapping but not electrogram morphology identifies stable sources for human atrial fibrillation: stable atrial fibrillation rotors and focal sources relate poorly to fractionated electrograms.Circ Arrhythm Electrophysiol. 2013 Feb;6(1):58-67. doi: 10.1161/CIRCEP.111.977264. Epub 2013 Feb 7. Circ Arrhythm Electrophysiol. 2013. PMID: 23392583 Free PMC article.
-
Coarse fibrillatory waves in atrial fibrillation predict success of electrical cardioversion.Ann Noninvasive Electrocardiol. 2018 Jul;23(4):e12528. doi: 10.1111/anec.12528. Epub 2017 Dec 22. Ann Noninvasive Electrocardiol. 2018. PMID: 29271577 Free PMC article.
-
Fibrillatory wave amplitude and thromboembolic risk in non-anticoagulated patients with atrial fibrillation.Ann Med. 2024 Dec;56(1):2317362. doi: 10.1080/07853890.2024.2317362. Epub 2024 Feb 13. Ann Med. 2024. PMID: 38350436 Free PMC article.
-
Electrocardiographic measurements of regional atrial fibrillation cycle length.Pacing Clin Electrophysiol. 2009 Mar;32 Suppl 1(Suppl 1):S66-71. doi: 10.1111/j.1540-8159.2008.02229.x. Pacing Clin Electrophysiol. 2009. PMID: 19250115 Free PMC article.
-
Organized Sources Are Spatially Conserved in Recurrent Compared to Pre-Ablation Atrial Fibrillation: Further Evidence for Non-Random Electrical Substrates.J Cardiovasc Electrophysiol. 2016 Jun;27(6):661-9. doi: 10.1111/jce.12964. Epub 2016 Apr 5. J Cardiovasc Electrophysiol. 2016. PMID: 26918971 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical