In vivo study of microbubbles as an MR susceptibility contrast agent
- PMID: 15334560
- DOI: 10.1002/mrm.20181
In vivo study of microbubbles as an MR susceptibility contrast agent
Abstract
The potential application of gas microbubbles as a unique intravascular susceptibility contrast agent for MRI has not been fully explored. In this study, the MR susceptibility effect of an ultrasound microbubble contrast agent, Optison, was studied with rat liver imaging at 7 T. Optison suspension in two different doses (0.15 mL/kg and 0.4 mL/kg) was injected into rats, and induced transverse relaxation rate increases (deltaR2*) of 29.1 +/- 1.6 s(-1) (N = 2) and 61.5 +/- 12.9 s(-1) (N = 6), respectively, in liver tissue. Liver uptake of intact albumin microbubbles was observed 10 min after injection. Eight of the 16 rats studied showed no susceptibility enhancement. This is probably attributable to the intravascular microbubble growth due to transmural CO2 supersaturation in the cecum and colon in small animals that causes microbubble aggregation and trapping in the inferior vena cava (IVC). In vitro deltaR2* measurements of Optison suspension at different concentrations are also reported.
Copyright 2004 Wiley-Liss, Inc.
Similar articles
-
Enhancement of gas-filled microbubble R2* by iron oxide nanoparticles for MRI.Magn Reson Med. 2010 Jan;63(1):224-9. doi: 10.1002/mrm.22184. Magn Reson Med. 2010. PMID: 19953509
-
Gas-filled microbubbles--a novel susceptibility contrast agent for brain and liver MRI.Annu Int Conf IEEE Eng Med Biol Soc. 2009;2009:4049-52. doi: 10.1109/IEMBS.2009.5333171. Annu Int Conf IEEE Eng Med Biol Soc. 2009. PMID: 19964096
-
Hemodynamic characteristics, myocardial kinetics and microvascular rheology of FS-069, a second-generation echocardiographic contrast agent capable of producing myocardial opacification from a venous injection.J Am Coll Cardiol. 1996 Nov 1;28(5):1292-300. doi: 10.1016/S0735-1097(96)00328-2. J Am Coll Cardiol. 1996. PMID: 8890829
-
Microbubbles as a novel contrast agent for brain MRI.Neuroimage. 2009 Jul 1;46(3):658-64. doi: 10.1016/j.neuroimage.2009.02.037. Epub 2009 Mar 6. Neuroimage. 2009. PMID: 19269337
-
Three Decades of Ultrasound Contrast Agents: A Review of the Past, Present and Future Improvements.Ultrasound Med Biol. 2020 Apr;46(4):892-908. doi: 10.1016/j.ultrasmedbio.2019.12.008. Epub 2020 Jan 13. Ultrasound Med Biol. 2020. PMID: 31941587 Review.
Cited by
-
Signal decay due to susceptibility-induced intravoxel dephasing on multiple air-filled cylinders: MRI simulations and experiments.MAGMA. 2008 Jul;21(4):261-71. doi: 10.1007/s10334-008-0119-1. Epub 2008 Jun 25. MAGMA. 2008. PMID: 18575911
-
Applications of magnetic microbubbles for theranostics.Theranostics. 2012;2(1):103-12. doi: 10.7150/thno.3464. Epub 2012 Jan 12. Theranostics. 2012. PMID: 22287990 Free PMC article.
-
Improving the detection specificity of endogenous MRI for reactive oxygen species (ROS).J Magn Reson Imaging. 2019 Aug;50(2):583-591. doi: 10.1002/jmri.26629. Epub 2019 Jan 7. J Magn Reson Imaging. 2019. PMID: 30614137 Free PMC article.
-
Evaluation of microbubbles as contrast agents for ultrasonography and magnetic resonance imaging.PLoS One. 2012;7(4):e34644. doi: 10.1371/journal.pone.0034644. Epub 2012 Apr 10. PLoS One. 2012. PMID: 22506039 Free PMC article.
-
Ultrasound-targeted microbubble destruction for chemotherapeutic drug delivery to solid tumors.J Ther Ultrasound. 2013 Jul 1;1:10. doi: 10.1186/2050-5736-1-10. eCollection 2013. J Ther Ultrasound. 2013. PMID: 25512858 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical