Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2004 Jan;15(1):91-8.
doi: 10.1023/b:jmsm.0000010102.26218.d1.

Carbon-carbon composite bearing materials in hip arthroplasty: analysis of wear and biological response to wear debris

Affiliations

Carbon-carbon composite bearing materials in hip arthroplasty: analysis of wear and biological response to wear debris

G I Howling et al. J Mater Sci Mater Med. 2004 Jan.

Abstract

Ultra-high molecular weight polyethylene wear particles have been implicated as the major cause of osteolysis, implant loosening and late aseptic failure in total hip arthroplasties in vivo. This study initially screened 22 carbon-carbon composite materials as alternatives for UHMWPE in joint bearings. New bearing materials should satisfy certain criteria--they should have good wear properties that at least match UHMWPE, and produce wear particles with low levels of cytotoxic and osteolytic activity. Initial screening was based on wear resistance determined in short-term tribological pin-on-plate tests. Three materials (HMU-PP(s), HMU-RC-P(s), and SMS-RC-P(s)) which had superior wear resistance were selected for long-term testing. All materials had very low wear factors and SMS-RC-P(s), which had a wear factor of 0.08 +/- 0.56 x 10(-7) mm3/Nm, was selected for the subsequent biological testing and particle size analysis. SMS-RC-P(s) showed good biocompatibility in bulk material form and also the wear particles had low cytotoxicity for L929 fibroblasts in culture compared to metal wear particles. Wear debris size analysis by transmission electron microscopy showed that the particles were very small, with the vast majority being under 100 nm in size, similar to metal wear particles. The potential osteolytic effect of SMS-RC-P(s) wear particles was investigated by culturing particles with human peripheral blood mononuclear cells and measuring TNFalpha production. SMS-RC-P(s) did not significantly stimulate TNFalpha production at a particle volume to cell number ratio of 80:1, indicating that the debris had a low osteolytic potential. The results of this study suggest that carbon-carbon composites, particularly those composed of PAN-based fibers may be important biomaterials in the development of next generation bearing surfaces for use in total joint replacements that have very low wear rates and reduced osteolytic and cytotoxic potential.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Biomaterials. 1998 Dec;19(24):2297-302 - PubMed
    1. J Bone Joint Surg Br. 1975 Nov;57(4):444-50 - PubMed
    1. Biomaterials. 2000 Oct;21(20):2033-44 - PubMed
    1. Proc Inst Mech Eng H. 2000;214(1):21-37 - PubMed
    1. J Bone Joint Surg Br. 1994 Jan;76(1):60-7 - PubMed

Publication types

LinkOut - more resources