Carbon-carbon composite bearing materials in hip arthroplasty: analysis of wear and biological response to wear debris
- PMID: 15338596
- DOI: 10.1023/b:jmsm.0000010102.26218.d1
Carbon-carbon composite bearing materials in hip arthroplasty: analysis of wear and biological response to wear debris
Abstract
Ultra-high molecular weight polyethylene wear particles have been implicated as the major cause of osteolysis, implant loosening and late aseptic failure in total hip arthroplasties in vivo. This study initially screened 22 carbon-carbon composite materials as alternatives for UHMWPE in joint bearings. New bearing materials should satisfy certain criteria--they should have good wear properties that at least match UHMWPE, and produce wear particles with low levels of cytotoxic and osteolytic activity. Initial screening was based on wear resistance determined in short-term tribological pin-on-plate tests. Three materials (HMU-PP(s), HMU-RC-P(s), and SMS-RC-P(s)) which had superior wear resistance were selected for long-term testing. All materials had very low wear factors and SMS-RC-P(s), which had a wear factor of 0.08 +/- 0.56 x 10(-7) mm3/Nm, was selected for the subsequent biological testing and particle size analysis. SMS-RC-P(s) showed good biocompatibility in bulk material form and also the wear particles had low cytotoxicity for L929 fibroblasts in culture compared to metal wear particles. Wear debris size analysis by transmission electron microscopy showed that the particles were very small, with the vast majority being under 100 nm in size, similar to metal wear particles. The potential osteolytic effect of SMS-RC-P(s) wear particles was investigated by culturing particles with human peripheral blood mononuclear cells and measuring TNFalpha production. SMS-RC-P(s) did not significantly stimulate TNFalpha production at a particle volume to cell number ratio of 80:1, indicating that the debris had a low osteolytic potential. The results of this study suggest that carbon-carbon composites, particularly those composed of PAN-based fibers may be important biomaterials in the development of next generation bearing surfaces for use in total joint replacements that have very low wear rates and reduced osteolytic and cytotoxic potential.
Similar articles
-
Biological response to wear debris generated in carbon based composites as potential bearing surfaces for artificial hip joints.J Biomed Mater Res B Appl Biomater. 2003 Nov 15;67(2):758-64. doi: 10.1002/jbm.b.10068. J Biomed Mater Res B Appl Biomater. 2003. PMID: 14598403
-
Biological reactions to wear debris in total joint replacement.Proc Inst Mech Eng H. 2000;214(1):21-37. doi: 10.1243/0954411001535219. Proc Inst Mech Eng H. 2000. PMID: 10718048 Review.
-
Morphological characteristics of total joint arthroplasty-derived ultra-high molecular weight polyethylene (UHMWPE) wear debris that provoke inflammation in a murine model of inflammation.J Biomed Mater Res A. 2003 Mar 1;64(3):457-64. doi: 10.1002/jbm.a.10368. J Biomed Mater Res A. 2003. PMID: 12579559
-
A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements.Proc Inst Mech Eng H. 2000;214(1):39-47. doi: 10.1243/0954411001535228. Proc Inst Mech Eng H. 2000. PMID: 10718049
-
Wear and osteolysis in total joint replacements.Acta Orthop Scand Suppl. 1998 Feb;278:1-16. Acta Orthop Scand Suppl. 1998. PMID: 9524528 Review.
Cited by
-
[Study on biocompatibility of carbon-based composites].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2018 Oct 25;35(5):740-748. doi: 10.7507/1001-5515.201708014. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2018. PMID: 30370713 Free PMC article. Chinese.
-
Wear Debris Characterization and Corresponding Biological Response: Artificial Hip and Knee Joints.Materials (Basel). 2014 Feb 10;7(2):980-1016. doi: 10.3390/ma7020980. Materials (Basel). 2014. PMID: 28788496 Free PMC article. Review.
-
Poly-ether-ether-ketone wear particles induce a pro-inflammatory phenotype in a human monocytic cell line.Front Bioeng Biotechnol. 2025 Aug 5;13:1507248. doi: 10.3389/fbioe.2025.1507248. eCollection 2025. Front Bioeng Biotechnol. 2025. PMID: 40837019 Free PMC article.
-
Significance of nano- and microtopography for cell-surface interactions in orthopaedic implants.J Biomed Biotechnol. 2007;2007(8):69036. doi: 10.1155/2007/69036. J Biomed Biotechnol. 2007. PMID: 18274618 Free PMC article.
-
Debris of carbon-fibers originated from a CFRP (pEEK) wrist-plate triggered a destruent synovitis in human.J Mater Sci Mater Med. 2016 Mar;27(3):50. doi: 10.1007/s10856-015-5664-3. Epub 2016 Jan 12. J Mater Sci Mater Med. 2016. PMID: 26758897
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous