Effect of passivation on the dissolution behavior of Ti6A14V and vacuum-brazed Ti6A14V in Hank's ethylene diamine tetra-acetic acid solution Part I Ion release
- PMID: 15348105
- DOI: 10.1023/a:1008916314329
Effect of passivation on the dissolution behavior of Ti6A14V and vacuum-brazed Ti6A14V in Hank's ethylene diamine tetra-acetic acid solution Part I Ion release
Abstract
This work aims to investigate the effects of three factors, namely: (1) two differently prepared materials (as-polished Ti6A14V and 2 h brazed Ti6A14V); (2) three different surface passivation treatments (34% nitric acid passivation, 400 degrees C heated in air, and aged in 100 degrees C de-ionized water); and (3) periods of immersion time (up to 32 days), on trace element release in Hank's ethylene diamine tetra-acetic acid (EDTA) solution. After passivation and autoclaving treatment, the specimens were immersed in 8.0 mM EDTA in Hank's solution and maintained at 37 degrees C for periods of time up to 32 days. The 400 degrees C -treated specimens exhibit a substantial reduction in constituent release, which may be attributed to the higher thickness and rutile structure of the surface oxides. For acid-passivated and water-aged treatments, a highly significant decrease in the trace levels of Ti, A1, and V is detected from the brazed Ti6A14V compared to those obtained from the Ti6A14V specimens. It is hypothesized that an anatase-rutile transformation of surface TiO_2 is likely to occur, accelerated by the elements of copper and nickel in the brazed specimens. In addition, a significant time-related decrease in constituent release rate is observed for all kinds of specimens throughout the 0-8 day experimental period. The implication of the results is discussed.
Copyright 1999 Kluwer Academic Publishers
Similar articles
-
Effect of passivation and surface modification on the dissolution behavior and nano-surface characteristics of Ti-6Al-4V in Hank/EDTA solution.J Mater Sci Mater Med. 2006 Jan;17(1):15-27. doi: 10.1007/s10856-006-6325-3. J Mater Sci Mater Med. 2006. PMID: 16389468
-
A comparison of the surface characteristics and ion release of Ti6Al4V and heat-treated Ti6Al4V.J Biomed Mater Res. 2000 Jun 15;50(4):499-511. doi: 10.1002/(sici)1097-4636(20000615)50:4<499::aid-jbm5>3.0.co;2-u. J Biomed Mater Res. 2000. PMID: 10756308
-
Surface characteristics of Ti6Al4V alloy: effect of materials, passivation and autoclaving.J Mater Sci Mater Med. 1998 Aug;9(8):439-48. doi: 10.1023/a:1008815316564. J Mater Sci Mater Med. 1998. PMID: 15348856
-
Effect of surface chemistries and characteristics of Ti6Al4V on the Ca and P adsorption and ion dissolution in Hank's ethylene diamine tetra-acetic acid solution.Biomaterials. 2002 Jul;23(14):2917-25. doi: 10.1016/s0142-9612(01)00420-3. Biomaterials. 2002. PMID: 12069333
-
Efficacy of Hank's balanced salt solution compared to other solutions in the preservation of the periodontal ligament. A systematic review and meta-analysis.PLoS One. 2018 Jul 13;13(7):e0200467. doi: 10.1371/journal.pone.0200467. eCollection 2018. PLoS One. 2018. PMID: 30005079 Free PMC article.
Cited by
-
PIXE micro-beam mapping of metals in human peri-implant tissues.J Mater Sci Mater Med. 2002 Nov;13(11):1083-9. doi: 10.1023/a:1020309108950. J Mater Sci Mater Med. 2002. PMID: 15348180
-
Characterization of Titanium Corrosion and Its Association With Peri-Implantitis Using Energy Dispersive X-ray Spectroscopy: A Case Report.Cureus. 2024 May 17;16(5):e60533. doi: 10.7759/cureus.60533. eCollection 2024 May. Cureus. 2024. PMID: 38887364 Free PMC article.
-
Effects of coating a titanium alloy with fibronectin on the expression of osteoblast gene markers in the MC3T3 osteoprogenitor cell line.Int J Oral Maxillofac Implants. 2012 Sep-Oct;27(5):1081-90. Int J Oral Maxillofac Implants. 2012. PMID: 23057020 Free PMC article.