Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloys used in metal on metal total hip replacements
- PMID: 15348136
- DOI: 10.1023/a:1026473723777
Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloys used in metal on metal total hip replacements
Abstract
The biological reactions to polyethylene wear debris have been shown to result in osteolysis and loosening of total hip arthroplasties. This has led to renewed interest in the use of metal on metal bearings in hip prostheses. This study employed uniaxial and biaxial multistation pin on plate reciprocators to assess how the carbon content of the cobalt chrome alloy and the types of motion affected the wear performance of the bearing surfaces and the morphology of the wear debris generated. The low carbon specimens demonstrated higher wear factors than both the mixed carbon pairings and the high carbon pairings. The biaxial motion decreased the wear rates of all specimens. Plate wear was significantly reduced by the biaxial motion, compared to pin wear. The metal wear particles isolated were an order of magnitude smaller than polyethylene particles, at 60-90 nm, and consequently, 100-fold more particles were produced per unit volume of wear compared to polyethylene. The low carbon specimens produced significantly larger particles than the other material combinations, although it is thought unlikely that the difference would be biologically significant in vivo. The volumetric wear rates were affected by the carbon content of the cobalt chrome alloy, the material combination used and type of motion applied. However, particle morphology was not affected by the carbon content of the alloy or the type of motion applied.
Copyright 1999 Kluwer Academic Publishers
Similar articles
-
Pin-on-plate studies on the effect of rotation on the wear of metal-on-metal samples.J Mater Sci Mater Med. 2001 Apr;12(4):299-303. doi: 10.1023/a:1011238902803. J Mater Sci Mater Med. 2001. PMID: 15348290
-
Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator.Biomed Mater Eng. 2001;11(2):143-57. Biomed Mater Eng. 2001. PMID: 11352113
-
Metal versus polyethylene wear particles in total hip replacements. A review.Clin Orthop Relat Res. 1996 Aug;(329 Suppl):S206-16. doi: 10.1097/00003086-199608001-00018. Clin Orthop Relat Res. 1996. PMID: 8769335 Review.
-
Ultra-high-molecular weight polyethylene wear: an in vitro comparison of acetabular metal types and polished surfaces.J Arthroplasty. 1999 Oct;14(7):860-6. doi: 10.1016/s0883-5403(99)90038-4. J Arthroplasty. 1999. PMID: 10537263
-
Biological effects of clinically relevant wear particles from metal-on-metal hip prostheses.Proc Inst Mech Eng H. 2006 Feb;220(2):355-69. doi: 10.1243/095441105X63291. Proc Inst Mech Eng H. 2006. PMID: 16669401 Review.
Cited by
-
[Uncemented arthroplasty of the hip].Orthopade. 2009 May;38(5):461-70; quiz 471-2. doi: 10.1007/s00132-009-1418-6. Orthopade. 2009. PMID: 19415234 Review. German.
-
Pin-on-plate studies on the effect of rotation on the wear of metal-on-metal samples.J Mater Sci Mater Med. 2001 Apr;12(4):299-303. doi: 10.1023/a:1011238902803. J Mater Sci Mater Med. 2001. PMID: 15348290
-
Effect of the environment on wear ranking and corrosion of biomedical CoCrMo alloys.J Mater Sci Mater Med. 2011 Mar;22(3):437-50. doi: 10.1007/s10856-010-4224-0. Epub 2011 Jan 11. J Mater Sci Mater Med. 2011. PMID: 21221728
-
Metal wear particles: What we know, what we do not know, and why.SAS J. 2009 Dec 1;3(4):133-42. doi: 10.1016/j.esas.2009.11.006. eCollection 2009. SAS J. 2009. PMID: 25802639 Free PMC article.
-
Wear of surface engineered metal-on-metal hip prostheses.J Mater Sci Mater Med. 2004 Mar;15(3):225-35. doi: 10.1023/b:jmsm.0000015482.24542.76. J Mater Sci Mater Med. 2004. PMID: 15334994
References
LinkOut - more resources
Full Text Sources