Boundary conditions during biaxial testing of planar connective tissues. Part 1: dynamic behavior
- PMID: 15348186
- DOI: 10.1023/a:1019896210320
Boundary conditions during biaxial testing of planar connective tissues. Part 1: dynamic behavior
Abstract
Current mechanical testing methods used to determine the biaxial properties of planar connective tissues may lead to artifactual observations of material behavior. The method of sample gripping affects the constraint on the extracellular fibers at the bounds of the sample. This applied constraint not only affects how the load is transferred to the sample, but also how the load is transmitted throughout the rest of the material - thereby influencing the resulting mechanical behavior of the tissue. In this study, we compared the dynamic biaxial mechanical response of pericardial tissue samples under two different gripping methods: (i) the common method of suturing sample edges and (ii) a new biaxial clamping method. Tissue samples were repeatedly testing using both gripping methods under the same conditions. The tissue samples appeared to be stiffer and less extensible when mechanically tested with clamped sample edges, as opposed to when tested with sutured sample edges. Thus, the influence of the sample boundaries affected the response of the material - precisely the situation to be avoided for reliable material testing. This casts doubt on whether any in vitro mechanical testing method can used to determine the "real" properties of the tissue since the boundary conditions of the tissue in situ are presently unknown.
Similar articles
-
Effect of sample geometry on the apparent biaxial mechanical behaviour of planar connective tissues.Biomaterials. 2005 Dec;26(35):7504-13. doi: 10.1016/j.biomaterials.2005.05.056. Biomaterials. 2005. PMID: 16002136
-
Effects of boundary conditions on the estimation of the planar biaxial mechanical properties of soft tissues.J Biomech Eng. 2005 Aug;127(4):709-15. doi: 10.1115/1.1933931. J Biomech Eng. 2005. PMID: 16121542
-
Imposed state of deformation determines local collagen fibre orientation but not apparent mechanical properties.Biomed Sci Instrum. 1999;35:51-6. Biomed Sci Instrum. 1999. PMID: 11143391
-
How important is sample alignment in planar biaxial testing of anisotropic soft biological tissues? A finite element study.J Mech Behav Biomed Mater. 2018 Dec;88:201-216. doi: 10.1016/j.jmbbm.2018.06.024. Epub 2018 Jul 18. J Mech Behav Biomed Mater. 2018. PMID: 30179794
-
Multiaxial mechanical behavior of biological materials.Annu Rev Biomed Eng. 2003;5:251-84. doi: 10.1146/annurev.bioeng.5.011303.120714. Epub 2003 Apr 18. Annu Rev Biomed Eng. 2003. PMID: 12730082 Review.
Cited by
-
Biaxial tension of fibrous tissue: using finite element methods to address experimental challenges arising from boundary conditions and anisotropy.J Biomech Eng. 2013 Feb;135(2):021004. doi: 10.1115/1.4023503. J Biomech Eng. 2013. PMID: 23445049 Free PMC article.
-
Combining displacement field and grip force information to determine mechanical properties of planar tissue with complicated geometry.J Biomech Eng. 2014 Nov;136(11):1145011-5. doi: 10.1115/1.4028193. J Biomech Eng. 2014. PMID: 25103887 Free PMC article.
-
Effect of cyclic deformation on xenogeneic heart valve biomaterials.PLoS One. 2019 Jun 13;14(6):e0214656. doi: 10.1371/journal.pone.0214656. eCollection 2019. PLoS One. 2019. PMID: 31194770 Free PMC article.
-
The time has come to extend the expiration limit of cryopreserved allograft heart valves.Cell Tissue Bank. 2021 Jun;22(2):161-184. doi: 10.1007/s10561-020-09843-2. Epub 2020 Jun 24. Cell Tissue Bank. 2021. PMID: 32583302 Review.
-
Mechanical Analysis of the Uterosacral Ligament: Swine vs. Human.Ann Biomed Eng. 2018 Dec;46(12):2036-2047. doi: 10.1007/s10439-018-2103-x. Epub 2018 Jul 26. Ann Biomed Eng. 2018. PMID: 30051246 Free PMC article.
References
LinkOut - more resources
Full Text Sources
Other Literature Sources