Material properties of various cements for use with vertebroplasty
- PMID: 15348196
- DOI: 10.1023/a:1013673830184
Material properties of various cements for use with vertebroplasty
Abstract
The purpose of the current study was to measure the material properties of various cements prepared per manufacturers' recommendations and of cements modified according to compositions developed by clinicians with experience performing vertebroplasty. Cement was prepared, cast to form cylindrical specimens, and tested in compression. The optical density of specimens from the various cement preparations was measured. Batches of Simplex P and Cranioplastic cement were also prepared with increased concentrations of BaSO4 (20% and 30%; and 10%, 20% and 30%, respectively) to evaluate the effect of additional BaSO4. Compressive modulus values for polymethylmethacrylate cements ranged from 2-2.7 GPa; some differences were significant (p<0.05). Compared with polymethylmethacrylate cements, Orthocomp exhibited almost twice the compressive modulus and 2-3 times the strength values. Increasing the BaSO4 concentration in Simplex P and Cranioplastic significantly (p<0.05) affected their material properties; however, it is unknown if these changes in material properties are clinically important. Optical density increased as a function of concentration of the opacifying agent added. The current study provides clinicians with information on changes in the material properties of bone cements when the compositions are altered in a manner consistent with the practice of vertebroplasty.
Similar articles
-
The effect of monomer-to-powder ratio on the material properties of cranioplastic.Bone. 1999 Aug;25(2 Suppl):27S-29S. doi: 10.1016/s8756-3282(99)00129-5. Bone. 1999. PMID: 10458270
-
The effect of the monomer-to-powder ratio on the material properties of acrylic bone cement.J Biomed Mater Res. 2002;63(4):396-9. doi: 10.1002/jbm.10258. J Biomed Mater Res. 2002. PMID: 12115746
-
Compressive fatigue properties of commercially available standard and low-modulus acrylic bone cements intended for vertebroplasty.J Mech Behav Biomed Mater. 2018 Jun;82:70-76. doi: 10.1016/j.jmbbm.2018.03.001. Epub 2018 Mar 8. J Mech Behav Biomed Mater. 2018. PMID: 29571115
-
Compressive mechanical properties and cytocompatibility of bone-compliant, linoleic acid-modified bone cement in a bovine model.J Mech Behav Biomed Mater. 2014 Apr;32:245-256. doi: 10.1016/j.jmbbm.2014.01.002. Epub 2014 Jan 15. J Mech Behav Biomed Mater. 2014. PMID: 24508711
-
Chemical and physical properties of bone cement for vertebroplasty.Biomed J. 2013 Jul-Aug;36(4):162-7. doi: 10.4103/2319-4170.112750. Biomed J. 2013. PMID: 23989310 Review.
Cited by
-
Ex vivo biomechanical comparison of hydroxyapatite and polymethylmethacrylate cements for use with vertebroplasty.AJNR Am J Neuroradiol. 2002 Nov-Dec;23(10):1647-51. AJNR Am J Neuroradiol. 2002. PMID: 12427616 Free PMC article.
-
Development prospects of curable osteoplastic materials in dentistry and maxillofacial surgery.Heliyon. 2020 Aug 11;6(8):e04686. doi: 10.1016/j.heliyon.2020.e04686. eCollection 2020 Aug. Heliyon. 2020. PMID: 32817899 Free PMC article. Review.
-
Current status of percutaneous vertebroplasty and percutaneous kyphoplasty--a review.Med Sci Monit. 2013 Oct 7;19:826-36. doi: 10.12659/MSM.889479. Med Sci Monit. 2013. PMID: 24097261 Free PMC article. Review.
-
Dynamic mechanical behavior of PMMA based bone cements in wet environment.J Mater Sci Mater Med. 2003 Jul;14(7):583-94. doi: 10.1023/a:1024014822277. J Mater Sci Mater Med. 2003. PMID: 15348419
-
Iodine doping of a photocuring, one-component embedding medium for µCT and histology.Br J Radiol. 2021 Dec;94(1128):20210129. doi: 10.1259/bjr.20210129. Epub 2021 Oct 29. Br J Radiol. 2021. PMID: 34714102 Free PMC article.
References
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous