Biological properties of copolymer of 2-hydroxyethyl methacrylate with sulfopropyl methacrylate
- PMID: 15348257
- DOI: 10.1023/a:1011297828955
Biological properties of copolymer of 2-hydroxyethyl methacrylate with sulfopropyl methacrylate
Abstract
Interaction of organism with non-toxic implanted polymers depends on the physicochemical properties of the implant surface, which influence the adsorption of bioactive proteins and subsequently adhesion and growth of cells. The synthetic hydrogels are known as poorly adhesive surfaces. In this study we demonstrated the adsorption of albumin, fibrinogen, fibronectin, basic fibroblast growth factor, heparin-binding epidermal growth factor-like growth factor and epidermal growth factor to poly(2-hydroxyethyl methacrylate) (pHEMA) and copolymer of 2-hydroxyethyl methacrylate (HEMA) and potassium salt of 3-sulfopropyl methacrylate (SPMAK). The adhesion and growth of 3T3 cells and human keratinocytes on surface of these polymers was tested without and with pretreatment of polymers with heparin-binding epidermal growth factor-like growth factor. The adhesion of mixture of human granulocytes and monocytes to these surfaces was also tested. The strips of both polymers were subcutaneously and intracerebrally implanted into the rat and the extent of foreign body reaction and brain biocompatibility was evaluated. The results showed the extensive adsorption of basic fibroblast growth factor and heparin-binding epidermal growth factor-like growth factor to copolymer containing SPMAK. However the adhesion (and growth) of cells to this type of copolymers was very low. Preadsorption of human plasma to pHEMA clearly stimulated the leukocyte adhesion in contrary to copolymer containing SPMAK. The extent of foreign-body reaction was significantly higher against the pHEMA compared to tested copolymer p(HEMA-co-SPMAK). In conclusion, the tested copolymer was a poorly adhesive substrate that is only poorly recognized by the non-specific immunity, although the adsorption of basic growth factors to this substrate is highly significant. Both polymers were well tolerated by the brain tissue. The phenotype of surrounding neurons was more close to the control neurons in the brain tissue surrounding the p(HEMA-co-SPMAK) implants.
Copyright 2001 Kluwer Academic Publishers
Similar articles
-
Influence of Surface Chemistry and Nanomechanical Properties of Methacrylate-Based Copolymer Thin Films on Keratocyte Cell Adhesion.ACS Appl Mater Interfaces. 2025 Apr 16;17(15):23222-23236. doi: 10.1021/acsami.4c21538. Epub 2025 Mar 11. ACS Appl Mater Interfaces. 2025. PMID: 40067198
-
Differential orientation and conformation of surface-bound keratinocyte growth factor on (hydroxyethyl)methacrylate, (hydroxyethyl)methacrylate/methyl methacrylate, and (hydroxyethyl)methacrylate/methacrylic acid hydrogel copolymers.Biointerphases. 2018 Oct 25;13(6):06E406. doi: 10.1116/1.5051655. Biointerphases. 2018. PMID: 30360629 Free PMC article.
-
Prevention of changes in platelet cytoplasmic free calcium levels by interaction with 2-hydroxyethyl methacrylate/styrene block copolymer surfaces.J Biomed Mater Res. 1993 Dec;27(12):1519-25. doi: 10.1002/jbm.820271208. J Biomed Mater Res. 1993. PMID: 8113239
-
Rat peritoneal macrophage adhesion to hydroxyethyl methacrylate-ethyl methacrylate copolymers and hydroxystyrene-styrene copolymers.J Biomed Mater Res. 1985 Nov-Dec;19(9):1101-15. doi: 10.1002/jbm.820190919. J Biomed Mater Res. 1985. PMID: 4086493
-
Cell biology of hydrogels.Biomaterials. 1993 Nov;14(14):1046-50. doi: 10.1016/0142-9612(93)90203-e. Biomaterials. 1993. PMID: 8312457 Review.
Cited by
-
Smaller, softer, lower-impedance electrodes for human neuroprosthesis: a pragmatic approach.Front Neuroeng. 2014 Apr 16;7:8. doi: 10.3389/fneng.2014.00008. eCollection 2014. Front Neuroeng. 2014. PMID: 24795621 Free PMC article.
References
LinkOut - more resources
Full Text Sources
Other Literature Sources