Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1997 Dec;8(12):747-51.
doi: 10.1023/a:1018556427716.

Activation status of platelet aggregates and platelet microparticles shed in sheared whole blood

Affiliations

Activation status of platelet aggregates and platelet microparticles shed in sheared whole blood

N P Rhodes et al. J Mater Sci Mater Med. 1997 Dec.

Abstract

The role of temperature and shear rate in the activation status of aggregating platelets and platelet microparticles (MPs) was investigated in a modified concentric-cylinder rotational viscometer. Whole blood anticoagulated with citrate was exposed to a range of shear rates typical of cardiopulmonary bypass circuits (0, 1000, 2000 and 4000 s(-1)) over four temperatures spanning hypothermic to mildly hyperthermic conditions (24, 30, 37 and 42 degrees C) for short durations (100 s). Aliquots of blood were double-stained for CD41 (platelet GPIIb/IIIa) and CD62 (P-selectin). Platelets, platelet aggregates, MPs and red blood cell-platelet and -MP aggregates were identified by flow cytometry by acquiring only CD41-positive particles and differentiating on a plot of CD41 versus forward light scatter. The activation status of each particle was quantified by measuring CD62 expression (alpha-granule release). A degree of correlation between the shedding of MPs and the formation of platelet-platelet aggregates was observed for the data as a whole (r=0.85 for p<0.01), although this trend was not observed for a shear rate of 4000 s(-1). The mean expression of CD62 on both platelets and MPs was maintained at a very low level for all temperature and shear rate combinations. There was, however, a number of very highly activated MPs associated with red blood cells at high shear rates.

PubMed Disclaimer

Similar articles

Cited by

References

    1. N Engl J Med. 1985 Jan 10;312(2):119-20 - PubMed
    1. Blood. 1993 Aug 15;82(4):1192-6 - PubMed
    1. Circulation. 1988 Sep;78(3 Pt 2):I179-84 - PubMed
    1. Blood. 1993 May 15;81(10):2554-65 - PubMed
    1. Blood Cells Mol Dis. 1995;21(3):217-31; discussion 231a - PubMed

LinkOut - more resources