Dosimetry of clinical neutron and proton beams: an overview of recommendations
- PMID: 15353710
- DOI: 10.1093/rpd/nch221
Dosimetry of clinical neutron and proton beams: an overview of recommendations
Abstract
Neutron therapy beams are obtained by accelerating protons or deuterons on Beryllium. These neutron therapy beams present comparable dosimetric characteristics as those for photon beams obtained with linear accelerators; for instance, the penetration of a p(65)+Be neutron beam is comparable with the penetration of an 8 MV photon beam. In order to be competitive with conventional photon beam therapy, the dosimetric characteristics of the neutron beam should therefore not deviate too much from the photon beam characteristics. This paper presents a brief summary of the neutron beams used in radiotherapy. The dosimetry of the clinical neutron beams is described. Finally, recent and future developments in the field of physics for neutron therapy is mentioned. In the last two decades, a considerable number of centres have established radiotherapy treatment facilities using proton beams with energies between 50 and 250 MeV. Clinical applications require a relatively uniform dose to be delivered to the volume to be treated, and for this purpose the proton beam has to be spread out, both laterally and in depth. The technique is called 'beam modulation' and creates a region of high dose uniformity referred to as the 'spread-out Bragg peak'. Meanwhile, reference dosimetry in these beams had to catch up with photon and electron beams for which a much longer tradition of dosimetry exists. Proton beam dosimetry can be performed using different types of dosemeters, such as calorimeters, Faraday cups, track detectors and ionisation chambers. National standard dosimetry laboratories will, however, not provide a standard for the dosimetry of proton beams. To achieve uniformity on an international level, the use of an ionisation chamber should be considered. This paper reviews and summarises the basic principles and recommendations for the absorbed dose determination in a proton beam, utilising ionisation chambers calibrated in terms of absorbed dose to water. These recommendations are based on the recent IAEA TRS398 Code of Practice: 'Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water'.
Similar articles
-
Absorbed dose to water determination with ionization chamber dosimetry and calorimetry in restricted neutron, photon, proton and heavy-ion radiation fields.Phys Med Biol. 2006 Aug 7;51(15):3667-82. doi: 10.1088/0031-9155/51/15/005. Epub 2006 Jul 12. Phys Med Biol. 2006. PMID: 16861773
-
A toolkit for epithermal neutron beam characterisation in BNCT.Radiat Prot Dosimetry. 2004;110(1-4):587-93. doi: 10.1093/rpd/nch151. Radiat Prot Dosimetry. 2004. PMID: 15353713
-
Dosimetric measurements with a brain equivalent plastic walled ionization chamber in an epithermal neutron beam.Radiat Prot Dosimetry. 2004;110(1-4):687-92. doi: 10.1093/rpd/nch149. Radiat Prot Dosimetry. 2004. PMID: 15353731
-
Dosimetry for ion beam radiotherapy.Phys Med Biol. 2010 Nov 7;55(21):R193-234. doi: 10.1088/0031-9155/55/21/R01. Epub 2010 Oct 15. Phys Med Biol. 2010. PMID: 20952816 Review.
-
Passive detectors for neutron personal dosimetry: state of the art.Radiat Prot Dosimetry. 2004;110(1-4):195-200. doi: 10.1093/rpd/nch129. Radiat Prot Dosimetry. 2004. PMID: 15353644 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources