Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2004 Jul;79(7):443-8.

[Evaluation of quantitative fit-testing of N95 filtering facepiece respirators using Mask-Fitting Tester and improvement of mask fitting by instruction]

[Article in Japanese]
Affiliations
  • PMID: 15354730

[Evaluation of quantitative fit-testing of N95 filtering facepiece respirators using Mask-Fitting Tester and improvement of mask fitting by instruction]

[Article in Japanese]
Yoshiko Kawabe et al. Kekkaku. 2004 Jul.

Abstract

Objective: To evaluate quantitative fitness of N95 filtering facepiece respirators (N95 Mask) using Mask Fitting Tester and improvement of fitness by instruction.

Materials and methods: One hundred and thirty-three health care workers working at our hospital were tested as to quantitative fitness of N95 Mask using Mask Fitting Tester Model MT-02, Roken type that counts particles more than 0.7 microm in diameter. Based on counting the number of particles more than 0.7 microm in diameter of the air inside and outside the mask, leakage rate is calculated. Permissible range of leakage rate is 10% or below. In case of leakage rate more than 10%, we instructed way of wearing N95 Mask or change a type of N95 Mask. We usually provide three types of N95 Mask.

Results: Eighty-seven (65.4%) out of 133 health care workers achieved leakage rate 10% or below at the first test. Forty-six (34.6%) who did not achieve leakage rate 10% or below at the first test received instruction or changed a mask type. Twenty-one (15.8%) achieved desired value by instruction and 19 (14.3%) by changing a mask type. But 6 (4.5 %) could not achieve desired value in spite of instruction or changing to another type of masks available to us. Leakage rate changed from 20.5 +/- 10.9% (10.1-58.6) to 6.3 +/- 4.9% (0-29.5) by instruction or changing a type of mask (p < 0.001). At the first test, mask fitness is better in male than female, and worse in workers who always use N95 Mask at isolation ward or laboratory room than workers who usually do not use N95 Mask. Main problems were choice of mask, fitness to nose, incorrect use of headband.

Conclusion: It is useful to evaluate N95 Mask quantitative fitness using Mask Fitting Tester Model MT-02, Roken type. At the first test, 34.6% of health care workers have large amount of leakage more than 10%, and by instruction or changing a mask type, most of them could achieve 10% or below. But 4.5% could not achieve desired value. On Infection control, it is important to test quantitative fitness of N95 Mask and to provide more than three types of N95 Mask.