Computer-aided detection performance in mammographic examination of masses: assessment
- PMID: 15358846
- DOI: 10.1148/radiol.2332040277
Computer-aided detection performance in mammographic examination of masses: assessment
Abstract
Purpose: To compare performance of two computer-aided detection (CAD) systems and an in-house scheme applied to five groups of sequentially acquired screening mammograms.
Materials and methods: Two hundred nineteen film-based mammographic examinations, classified into five groups, were included in this study. Group 1 included 58 examinations in which verified malignant masses were detected during screening; group 2, 39 in which all available latest examinations were performed prior to diagnosis of these malignant masses (subset of 39 women from group 1); group 3, 22 in which findings were interpreted as negative but were verified as cancer within 1 year from the negative interpretation (missed cancers); group 4, 50 in which findings were negative and patients were not recalled for additional procedures; and group 5, 50 in which patients were recalled for additional procedures and findings were negative for cancer. In all examinations, images were processed with two Food and Drug Administration-approved commercially available CAD systems and an in-house scheme. Performance levels in terms of true-positive detection rates and number of false-positive identifications per image and per examination were compared.
Results: Mass detection rates in positive examinations (group 1) were 67%-72%. Detection rates among three systems were not significantly different (P > .05). In 50 negative screening examinations (group 4), false-positive rates ranged from 1.08 to 1.68 per four-view examination. Performance level differences among systems were significant for false-positive rates (P = .008). Performance of all systems was at levels lower than publicly suggested in some retrospective studies. False-positive CAD cueing rates were significantly higher for negative examinations in which patients were recalled (group 5) than they were for those in which patients were not recalled (group 4) (P < or = .002).
Conclusion: Performance of CAD systems for mass detection at mammography varies significantly, depending on examination and system used. Actual performance of all systems in clinical environment can be improved.
Similar articles
-
Computer-aided detection in full-field digital mammography: sensitivity and reproducibility in serial examinations.Radiology. 2008 Jan;246(1):71-80. doi: 10.1148/radiol.2461062072. Radiology. 2008. PMID: 18096530
-
Screening mammography-detected cancers: sensitivity of a computer-aided detection system applied to full-field digital mammograms.Radiology. 2007 Jul;244(1):104-11. doi: 10.1148/radiol.2441060756. Epub 2007 May 16. Radiology. 2007. PMID: 17507722
-
Computer-aided detection output on 172 subtle findings on normal mammograms previously obtained in women with breast cancer detected at follow-up screening mammography.Radiology. 2004 Mar;230(3):811-9. doi: 10.1148/radiol.2303030254. Epub 2004 Feb 5. Radiology. 2004. PMID: 14764891
-
Computer-aided detection in mammography.Clin Radiol. 2004 May;59(5):390-9. doi: 10.1016/j.crad.2003.11.017. Clin Radiol. 2004. PMID: 15081844 Review.
-
Computer-aided detection for screening mammography.Acad Radiol. 2004 Oct;11(10):1139-43. doi: 10.1016/j.acra.2004.07.009. Acad Radiol. 2004. PMID: 15530806 Review.
Cited by
-
A new and fast image feature selection method for developing an optimal mammographic mass detection scheme.Med Phys. 2014 Aug;41(8):081906. doi: 10.1118/1.4890080. Med Phys. 2014. PMID: 25086537 Free PMC article.
-
Dual system approach to computer-aided detection of breast masses on mammograms.Med Phys. 2006 Nov;33(11):4157-68. doi: 10.1118/1.2357838. Med Phys. 2006. PMID: 17153394 Free PMC article.
-
Reduction of false-positive recalls using a computerized mammographic image feature analysis scheme.Phys Med Biol. 2014 Aug 7;59(15):4357-73. doi: 10.1088/0031-9155/59/15/4357. Epub 2014 Jul 17. Phys Med Biol. 2014. PMID: 25029964 Free PMC article.
-
Matching breast masses depicted on different views a comparison of three methods.Acad Radiol. 2009 Nov;16(11):1338-47. doi: 10.1016/j.acra.2009.05.005. Epub 2009 Jul 25. Acad Radiol. 2009. PMID: 19632867 Free PMC article.
-