Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2004 Aug;9(3):392-6.
doi: 10.1111/j.1440-1843.2004.00607.x.

Computed tomography-guided transthoracic fine-needle aspiration in diagnosis of lung cancer: a comparison of single-pass needle and multiple-pass coaxial needle systems and the value of immediate cytological assessment

Affiliations
Comparative Study

Computed tomography-guided transthoracic fine-needle aspiration in diagnosis of lung cancer: a comparison of single-pass needle and multiple-pass coaxial needle systems and the value of immediate cytological assessment

Cağla Uyanusta Küçük et al. Respirology. 2004 Aug.

Abstract

Objectives: The aim of the present study was to compare single-pass needle and multiple-pass coaxial needle systems and to evaluate the value of immediate cytological assessment during the procedure in the diagnosis of lung cancer with CT-guided transthoracic fine-needle aspiration.

Methodology: One hundred and forty-three consecutive patients who underwent CT-guided transthoracic fine-needle aspiration were divided into three groups. In the first group (group A, 48 patients), a single-pass needle was used for aspiration, but immediate cytological examination was not performed. In the second group (group B, 48 patients), a single-pass needle was used for aspiration and a pathologist immediately assessed the adequacy of the sample obtained. In the third group (group C, 47 patients), a multiple-pass coaxial needle was used for aspiration and a pathologist immediately assessed the adequacy of the sample obtained.

Results: The mean number of fine-needle aspirations was 1.25 in group A, 1.39 in group B and 1.34 in group C (group A vs group B, P = 0.08). The diagnostic accuracy was 83.3, 97.9 and 100.0%, respectively (group A vs group B, P = 0.03; group B vs group C, P > 0.05). Although immediate cytological assessment resulted in adequate samples being obtained from all patients in groups B and C, adequate samples were obtained in 41 of 48 patients (85.4%) in group A (P = 0.004). There was no statistically significant difference among the groups with respect to the rate of pneumothorax.

Conclusions: A single-pass needle technique in transthoracic fine-needle aspiration is preferred because there is no significant difference between single-pass needle and multiple-pass coaxial needle systems with respect to the diagnostic accuracy and the complication rate and, in addition, the single-pass needle has a lower cost. The results of the present study suggest that immediate cytological assessment during the procedure reduces an inadequate sampling rate, thus increasing the diagnostic accuracy of the procedure.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources