Efficacy of repeat pulmonary vein isolation procedures in patients with recurrent atrial fibrillation
- PMID: 15363079
- DOI: 10.1046/j.1540-8167.2004.04052.x
Efficacy of repeat pulmonary vein isolation procedures in patients with recurrent atrial fibrillation
Abstract
Introduction: Pulmonary vein (PV) isolation is effective in the treatment of most patients with atrial fibrillation (AF). Some advocate the addition of linear ablation techniques to improve efficacy; however, previous studies suggest recurrent PV conduction is responsible for AF recurrence. The aim of this study was to determine the effectiveness of repeat PV isolation in patients with recurrent AF after an initial ablation procedure and to determine if any patient characteristics predict failure of repeat PV isolation procedures.
Methods and results: Seventy-four patients with two or more AF ablation procedures using selective PV isolation were included. PV isolation was guided with multielectrode ring catheter recordings, electroanatomic mapping, and intracardiac electrocardiography. Radiofrequency energy was delivered using a 4-mm-tip catheter (maximum 40 W, 52 degrees C); cooled-tip ablation was performed in 10 patients. Linear ablation was not performed. Antiarrhythmic drugs were continued for at least 6 weeks after ablation; AF episodes during this period were censored. Reconnection of one or more segments of previously ablated PVs was observed in 97% of patients; reconnected PVs served as the trigger for AF in 77%. Repeat PV isolation resulted in AF control (cure or 90% reduction in AF episodes) in 64 patients (86%) over a follow-up period of 9.1 +/- 6.7 months. "High-risk" characteristics such as left atrial enlargement, persistent AF, or mitral regurgitation did not predict failure of repeat PV isolation procedures.
Conclusion: Recurrent AF following selective PV isolation is overwhelmingly associated with PV electrical reconnection. Repeat PV isolation without linear ablation provides effective treatment for recurrent AF in patients in whom an initial PV isolation procedure failed, independent of clinical characteristics.
Comment in
-
Repeat ablation for atrial fibrillation: just a second go-around?J Cardiovasc Electrophysiol. 2004 Sep;15(9):1056-7. doi: 10.1046/j.1540-8167.2004.04417.x. J Cardiovasc Electrophysiol. 2004. PMID: 15363080 No abstract available.
Similar articles
-
Limitations of dormant conduction as a predictor of atrial fibrillation recurrence and pulmonary vein reconnection after catheter ablation.Pacing Clin Electrophysiol. 2015 May;38(5):598-607. doi: 10.1111/pace.12596. Epub 2015 Feb 14. Pacing Clin Electrophysiol. 2015. PMID: 25644741
-
Mechanisms of recurrent atrial fibrillation after pulmonary vein isolation by segmental ostial ablation.Heart Rhythm. 2004 Jul;1(2):197-202. doi: 10.1016/j.hrthm.2004.03.071. Heart Rhythm. 2004. PMID: 15851153
-
Clinical predictors and outcomes associated with acute return of pulmonary vein conduction during pulmonary vein isolation for treatment of atrial fibrillation.Heart Rhythm. 2006 Sep;3(9):1024-8. doi: 10.1016/j.hrthm.2006.05.007. Epub 2006 May 9. Heart Rhythm. 2006. PMID: 16945795
-
Catheter Ablation of Paroxysmal Atrial Fibrillation: Have We Achieved Cure with Pulmonary Vein Isolation?Methodist Debakey Cardiovasc J. 2015 Apr-Jun;11(2):71-5. doi: 10.14797/mdcj-11-2-71. Methodist Debakey Cardiovasc J. 2015. PMID: 26306122 Free PMC article. Review.
-
First Experience Using a Novel Variable Loop Catheter for Mapping and Pulsed Field Ablation of Atrial Fibrillation.Pacing Clin Electrophysiol. 2025 May;48(5):471-479. doi: 10.1111/pace.15177. Epub 2025 Mar 28. Pacing Clin Electrophysiol. 2025. PMID: 40153431 Free PMC article. Review.
Cited by
-
The adjunctive effect for left pulmonary vein isolation of vein of Marshall ethanol infusion in persistent atrial fibrillation.Europace. 2023 Feb 16;25(2):441-449. doi: 10.1093/europace/euac219. Europace. 2023. PMID: 36504017 Free PMC article.
-
Pulmonary vein isolation using a compliant endoscopic laser balloon ablation system in a swine model.J Interv Card Electrophysiol. 2010 Oct;29(1):1-9. doi: 10.1007/s10840-010-9501-9. Epub 2010 Jul 13. J Interv Card Electrophysiol. 2010. PMID: 20625804
-
Paroxysmal atrial fibrillation ablation: Achieving permanent pulmonary vein isolation by point-by-point radiofrequency lesions.World J Cardiol. 2017 Mar 26;9(3):230-240. doi: 10.4330/wjc.v9.i3.230. World J Cardiol. 2017. PMID: 28400919 Free PMC article. Review.
-
Surgical Ablation of Atrial Fibrillation: is Electrical Isolation of the Pulmonary Veins a Must?J Atr Fibrillation. 2016 Jun 30;9(1):1426. doi: 10.4022/jafib.1426. eCollection 2016 Jun-Jul. J Atr Fibrillation. 2016. PMID: 27909520 Free PMC article. Review.
-
Recurrence of paroxysmal atrial fibrillation after cryoisolation of the pulmonary veins. Is a "redo" procedure using the cryoballoon useful?J Interv Card Electrophysiol. 2013 Apr;36(3):287-95; discussion 295. doi: 10.1007/s10840-012-9725-y. Epub 2012 Nov 7. J Interv Card Electrophysiol. 2013. PMID: 23132349 Clinical Trial.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials