Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients
- PMID: 15375649
- DOI: 10.1007/s00134-004-2361-y
Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients
Abstract
Objective: In mechanically ventilated patients inspiratory increase in pleural pressure during lung inflation may produce complete or partial collapse of the superior vena cava. Occurrence of this collapse suggests that at this time external pressure exerted by the thoracic cavity on the superior vena cava is greater than the venous pressure required to maintain the vessel fully open. We tested the hypothesis that measurement of superior vena caval collapsibility would reveal the need for volume expansion in a given septic patient.
Design and setting: Prospective data collection for 66 successive patients in septic shock admitted in a medical intensive care unit and mechanically ventilated for an associated acute lung injury.
Measurements and results: We simultaneously measured superior vena caval collapsibility by echocardiography and cardiac index by the Doppler technique at baseline and after a 10 ml/kg volume expansion by 6% hydroxyethyl starch in 30 min. The threshold superior vena caval collapsibility of 36%, calculated as (maximum diameter on expiration-minimum diameter on inspiration)/maximum diameter on expiration, allowed discrimination between responders (defined by an increase in cardiac index of at least 11% induced by volume expansion) and nonresponders, with a sensitivity of 90% and a specificity of 100%.
Conclusions: Superior vena cava measurement should be systematically performed during routine echocardiography in septic shock as it gives an accurate index of fluid responsiveness.
Comment in
-
Evaluation of fluid responsiveness in ventilated septic patients: back to venous return.Intensive Care Med. 2004 Sep;30(9):1699-701. doi: 10.1007/s00134-004-2362-x. Epub 2004 Jun 25. Intensive Care Med. 2004. PMID: 15221127 No abstract available.
-
Superior vena cava collapsibility as a gauge of volume status in ventilated septic patients.Intensive Care Med. 2004 Dec;30(12):2282; author reply 2283. doi: 10.1007/s00134-004-2473-4. Epub 2004 Oct 12. Intensive Care Med. 2004. PMID: 15480562 No abstract available.
Similar articles
-
Diagnostic Accuracy of the Inferior Vena Cava Collapsibility to Predict Fluid Responsiveness in Spontaneously Breathing Patients With Sepsis and Acute Circulatory Failure.Crit Care Med. 2017 Mar;45(3):e290-e297. doi: 10.1097/CCM.0000000000002090. Crit Care Med. 2017. PMID: 27749318
-
Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients.Intensive Care Med. 2004 Sep;30(9):1740-6. doi: 10.1007/s00134-004-2259-8. Epub 2004 Mar 18. Intensive Care Med. 2004. PMID: 15034650 Clinical Trial.
-
Predicting preload responsiveness using simultaneous recordings of inferior and superior vena cavae diameters.Crit Care. 2014 Sep 5;18(5):473. doi: 10.1186/s13054-014-0473-5. Crit Care. 2014. PMID: 25189403 Free PMC article.
-
Superior vena cava collapsibility index as a predictor of fluid responsiveness: a systematic review with meta-analysis.Anaesthesiol Intensive Ther. 2024;56(3):169-176. doi: 10.5114/ait.2024.142797. Anaesthesiol Intensive Ther. 2024. PMID: 39451163 Free PMC article.
-
Optimizing oxygen delivery in the critically ill: assessment of volume responsiveness in the septic patient.J Emerg Med. 2014 Nov;47(5):608-15. doi: 10.1016/j.jemermed.2014.06.015. Epub 2014 Aug 1. J Emerg Med. 2014. PMID: 25088530 Review.
Cited by
-
A pilot study on safety and clinical utility of a single-use 72-hour indwelling transesophageal echocardiography probe.Intensive Care Med. 2013 Apr;39(4):629-35. doi: 10.1007/s00134-012-2797-4. Epub 2013 Jan 4. Intensive Care Med. 2013. PMID: 23287876 Clinical Trial.
-
Echocardiography in the intensive care unit: from evolution to revolution?Intensive Care Med. 2008 Feb;34(2):243-9. doi: 10.1007/s00134-007-0923-5. Epub 2007 Nov 9. Intensive Care Med. 2008. PMID: 17992511 Review.
-
Perioperative echocardiography-guided hemodynamic therapy in high-risk patients: a practical expert approach of hemodynamically focused echocardiography.J Clin Monit Comput. 2021 Apr;35(2):229-243. doi: 10.1007/s10877-020-00534-7. Epub 2020 May 26. J Clin Monit Comput. 2021. PMID: 32458170 Free PMC article. Review.
-
Applied physiology at the bedside to drive resuscitation algorithms.J Cardiothorac Vasc Anesth. 2014 Dec;28(6):1642-59. doi: 10.1053/j.jvca.2014.07.005. J Cardiothorac Vasc Anesth. 2014. PMID: 25479921 Free PMC article. Review.
-
Does inferior vena cava respiratory variability predict fluid responsiveness in spontaneously breathing patients?Crit Care. 2015 Nov 13;19:400. doi: 10.1186/s13054-015-1100-9. Crit Care. 2015. PMID: 26563768 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical