Heparin-coated angiographic catheters: an in vivo comparison of three coating methods with different heparin release profiles
- PMID: 15383856
- DOI: 10.1007/s00270-003-4035-5
Heparin-coated angiographic catheters: an in vivo comparison of three coating methods with different heparin release profiles
Abstract
We evaluated in vivo anti-thrombogenic effects of three different heparin-coated angiographic catheters with different heparin release profiles. Three different types of heparin-coated 5 French angiographic catheters (rapidly-heparin-releasing, slowly-heparin-releasing, and heparin-adherent catheters) were prepared by coating amphiphilic or hydrophobic heparin derivatives in order to regulate heparin elution. After incubation time of 30 minutes in the arteries of dogs, the amount of thrombus deposition, measured as dry weight, was compared in 10 sets of the three heparin-coated catheters and a non-coated catheter used as control. The surface morphology of catheters after their withdrawal was studied by scanning electron microscopy. The amount of thrombus deposition on the non-coated catheter (374.6 +/- 11.6 mg, mean +/- SD) was significantly larger than those on the rapidly-heparin-releasing (52.0 +/- 12.6), slowly-heparin-releasing (70.4 +/- 23.1), and heparin-adherent catheters (103.7 +/- 39.9) ( p < 0.001, each). The thrombus weights in the three heparin-coated catheters were not statistically different. The scanning electron microscopy showed crusts on the catheter surface, which were thickest in the non-coated catheters. We concluded that the thrombus formation inside a catheter is significantly decreased if the catheter is treated with any of the three heparin-coating methods used in this study. The in vivo anti-thrombogenic effects of these coating methods are not significantly different despite their different heparin release profiles.
Similar articles
-
Mechanism of antithrombogenicity of a new heparinized hydrophilic polymer: chronic in vivo studies and clinical application.Trans Am Soc Artif Intern Organs. 1975;21:436-49. Trans Am Soc Artif Intern Organs. 1975. PMID: 1146018
-
Heparin release from thermosensitive polymer coatings: in vivo studies.J Biomed Mater Res. 1995 Jul;29(7):811-21. doi: 10.1002/jbm.820290705. J Biomed Mater Res. 1995. PMID: 7593019
-
Thrombogenicity of heparin- and non-heparin-coated catheters: clinical trail.AJR Am J Roentgenol. 1982 Nov;139(5):957-61. doi: 10.2214/ajr.139.5.957. AJR Am J Roentgenol. 1982. PMID: 6751056 Clinical Trial.
-
Types of urethral catheters for management of short-term voiding problems in hospitalized adults: a short version Cochrane review.Neurourol Urodyn. 2008;27(8):738-46. doi: 10.1002/nau.20645. Neurourol Urodyn. 2008. PMID: 18951451 Review.
-
Catheter coatings, blood flow, and biocompatibility.Semin Hematol. 1991 Oct;28(4 Suppl 7):42-8; discussion 66-8. Semin Hematol. 1991. PMID: 1822610 Review.
Cited by
-
Understanding the Basics of Commonly Used Wires in Interventional Radiology.Semin Intervent Radiol. 2021 Oct;38(4):504-508. doi: 10.1055/s-0041-1735611. Epub 2021 Oct 7. Semin Intervent Radiol. 2021. PMID: 34629722 Free PMC article. Review. No abstract available.
-
Understanding the Basics of Commonly Used Wires in Interventional Radiology.Semin Intervent Radiol. 2021 Nov 24;38(5):560-564. doi: 10.1055/s-0041-1739159. eCollection 2021 Dec. Semin Intervent Radiol. 2021. PMID: 34853502 Free PMC article. Review.
-
The Use of Heparin during Endovascular Peripheral Arterial Interventions: A Synopsis.Scientifica (Cairo). 2016;2016:1456298. doi: 10.1155/2016/1456298. Epub 2016 Apr 17. Scientifica (Cairo). 2016. PMID: 27190678 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical