Coil-based artifact reduction
Abstract
Multiple MRI receiver coils provide extra information and can enable the reconstruction of multiple images using data from different combinations of coils. Comparison of these images shows that artifacts due to motion or flowing blood appear with different intensities due to the differing coil sensitivities. Typically, the artifact appears amplified in regions of low coil sensitivity. An optimization routine was developed to correct for the artifact by comparing reconstructions from various coil combinations and favoring a self-consistent solution. It is demonstrated that images artifacted by blood flowing in the aorta, or translational motion of the head, can be improved.
Similar articles
-
POCS-enhanced correction of motion artifacts in parallel MRI.Magn Reson Med. 2010 Apr;63(4):1104-10. doi: 10.1002/mrm.22254. Magn Reson Med. 2010. PMID: 20373413 Free PMC article.
-
Interactions between head motion and coil sensitivity in accelerated fMRI.J Neurosci Methods. 2016 Sep 1;270:46-60. doi: 10.1016/j.jneumeth.2016.06.005. Epub 2016 Jun 8. J Neurosci Methods. 2016. PMID: 27288867
-
Effects of MR surface coils on PET quantification.Med Phys. 2011 Jun;38(6):2948-56. doi: 10.1118/1.3583697. Med Phys. 2011. PMID: 21815368 Free PMC article.
-
Artifact reduction using parallel imaging methods.Top Magn Reson Imaging. 2004 Aug;15(4):267-75. doi: 10.1097/01.rmr.0000143782.39690.8a. Top Magn Reson Imaging. 2004. PMID: 15548957 Review.
-
Parallel magnetic resonance imaging.Phys Med Biol. 2007 Apr 7;52(7):R15-55. doi: 10.1088/0031-9155/52/7/R01. Epub 2007 Mar 9. Phys Med Biol. 2007. PMID: 17374908 Review.
Cited by
-
Nonrigid motion correction in 3D using autofocusing with localized linear translations.Magn Reson Med. 2012 Dec;68(6):1785-97. doi: 10.1002/mrm.24189. Epub 2012 Feb 3. Magn Reson Med. 2012. PMID: 22307933 Free PMC article.
-
Motion correction in MRI of the brain.Phys Med Biol. 2016 Mar 7;61(5):R32-56. doi: 10.1088/0031-9155/61/5/R32. Epub 2016 Feb 11. Phys Med Biol. 2016. PMID: 26864183 Free PMC article. Review.
-
Reducing ghosting due to k-space discontinuities in fast spin echo (FSE) imaging by a new combination of k-space ordering and parallel imaging.J Magn Reson. 2009 Sep;200(1):119-25. doi: 10.1016/j.jmr.2009.06.013. Epub 2009 Jun 21. J Magn Reson. 2009. PMID: 19608444 Free PMC article.
-
Correction of B 0-induced geometric distortion variations in prospective motion correction for 7T MRI.MAGMA. 2016 Jun;29(3):319-32. doi: 10.1007/s10334-015-0515-2. Epub 2016 Feb 9. MAGMA. 2016. PMID: 26861047 Free PMC article.
-
Motion correction using coil arrays (MOCCA) for free-breathing cardiac cine MRI.Magn Reson Med. 2011 Aug;66(2):467-75. doi: 10.1002/mrm.22854. Epub 2011 Feb 24. Magn Reson Med. 2011. PMID: 21773986 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical