Patient tolerance and resource utilization associated with an arterial closure versus an external compression device after percutaneous coronary intervention
- PMID: 15390237
- DOI: 10.1002/ccd.20161
Patient tolerance and resource utilization associated with an arterial closure versus an external compression device after percutaneous coronary intervention
Abstract
We assessed patient tolerance and resource utilization of using the AngioSeal closure device versus assisted manual compression using the Femostop device after percutaneous coronary intervention (PCI). Patients undergoing PCI with clean arterial access and no procedural hematoma were randomized to receive the AngioSeal or Femostop device to achieve femoral arterial hemostasis. Times from procedure end to removal from angiography table, hemostasis, ambulation, and hospital discharge were recorded. Bedside nursing/medical officer care time, vascular complications, and disposable use were also documented. Patient comfort was assessed using Present Pain Intensity and Visual Analogue scales at baseline, 4 hr, 8 hr, and the morning after the procedure. One hundred twenty-two patients were enrolled (62 AngioSeal, 60 Femostop). Patients in the AngioSeal group took longer to be removed from the angiography table (11 +/- 4 vs. 9 +/- 3 min; P = 0.002) compared with the Femostop group. Time to hemostasis (0.4 +/- 1.1 vs. 6.4 +/- 1.7 hr; P < 0.001) and ambulation (17 +/- 8 vs. 22 +/- 13 hr; P = 0.004) were less in the AngioSeal group, although time to discharge was not different. Nursing and medical officer time was no different. Disposables including device cost were higher in the AngioSeal group (209 dollars +/- 13 vs. 53 dollars +/- 9; P < 0.001). On a Visual Analogue scale, patients reported more pain at 4 hr (P < 0.001) and 8 hr (P < 0.001) in the Femostop group. The worst amount of pain at any time point was also more severe in the Femostop group (P < 0.001). Similar results were found on a Present Pain Intensity scale of pain. There were no differences in ultrasound-determined vascular complications (two each). Femoral access site closure using the AngioSeal device resulted in a small delay in leaving the angiography suite and a higher disposable cost compared to using the Femostop device. However, patients receiving the AngioSeal were able to ambulate sooner and reported less pain, which may justify the increased costs involved.
(c) 2004 Wiley-Liss, Inc.
Similar articles
-
A randomized trial comparing compression, Perclose Proglide and Angio-Seal VIP for arterial closure following percutaneous coronary intervention: the CAP trial.Catheter Cardiovasc Interv. 2008 Jan 1;71(1):1-5. doi: 10.1002/ccd.21333. Catheter Cardiovasc Interv. 2008. PMID: 18098171 Clinical Trial.
-
Comparison of costs and safety of a suture-mediated closure device with conventional manual compression after coronary artery interventions.Catheter Cardiovasc Interv. 2002 Nov;57(3):297-302. doi: 10.1002/ccd.10294. Catheter Cardiovasc Interv. 2002. PMID: 12410501 Clinical Trial.
-
Vascular complications after percutaneous coronary intervention following hemostasis with the Mynx vascular closure device versus the AngioSeal vascular closure device.J Invasive Cardiol. 2010 Apr;22(4):175-8. J Invasive Cardiol. 2010. PMID: 20351388
-
Vascular complications associated with arteriotomy closure devices in patients undergoing percutaneous coronary procedures: a meta-analysis.J Am Coll Cardiol. 2004 Sep 15;44(6):1200-9. doi: 10.1016/j.jacc.2004.06.048. J Am Coll Cardiol. 2004. PMID: 15364320 Review.
-
An evidence-based approach to femoral arterial access and closure.Rev Cardiovasc Med. 2008 Winter;9(1):7-18. Rev Cardiovasc Med. 2008. PMID: 18418305 Review.
Cited by
-
Incidence of delayed angiographic femoral artery complications using the EXOSEAL vascular closure device.Interv Neuroradiol. 2015 Jun;21(3):401-6. doi: 10.1177/1591019915581776. Epub 2015 May 26. Interv Neuroradiol. 2015. PMID: 26015532 Free PMC article.
-
A retrospective review on feasibility and safety of a new pneumatic compression device for femoral arteriotomy hemostasis.Korean J Radiol. 2012 Jan-Feb;13(1):61-5. doi: 10.3348/kjr.2012.13.1.61. Epub 2011 Dec 23. Korean J Radiol. 2012. PMID: 22247637 Free PMC article.
-
The frequency of vascular complications associated with the use of vascular closure devices varies by indication for cardiac catheterization.Clin Res Cardiol. 2011 Sep;100(9):789-95. doi: 10.1007/s00392-011-0313-4. Epub 2011 Apr 11. Clin Res Cardiol. 2011. PMID: 21479967
-
Vascular closure devices for femoral arterial puncture site haemostasis.Cochrane Database Syst Rev. 2016 Mar 7;3(3):CD009541. doi: 10.1002/14651858.CD009541.pub2. Cochrane Database Syst Rev. 2016. PMID: 26948236 Free PMC article.
-
A cost-minimization analysis of the angio-seal vascular closure device following percutaneous coronary intervention.Am J Cardiol. 2007 Mar 15;99(6):766-70. doi: 10.1016/j.amjcard.2006.10.032. Epub 2007 Jan 22. Am J Cardiol. 2007. PMID: 17350361 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous