Flow-induced platelet activation in bileaflet and monoleaflet mechanical heart valves
Abstract
A study was conducted to measure in vitro the procoagulant properties of platelets induced by flow through Carbomedics bileaflet and Bjork-Shiley monoleaflet mechanical heart valves (MHVs). Valves were mounted in a left ventricular assist device, and platelets were circulated through them under pulsatile flow. Platelet activation states (PAS) were measured during circulation using a modified prothrombinase method. Computational fluid dynamics (CFD) simulations of turbulent, transient, and non-Newtonian blood flow patterns generated by the two valve designs were done using the Wilcox k - w turbulence model, and platelet shear-stress histories (the integral of shear-stress exposure with respect to time) through the two MHVs were calculated. PAS measurements indicated that the bileaflet MHV activated platelets at a rate more than twice that observed with the monoleaflet MHV. Turbulent flow patterns were evident in CFD simulations for both valves, and corroborated the PAS observations, showing that, for particles close to the leaflet(s), shear-stress exposure in the bileaflet MHV can be more than four times that in the monoleaflet valve.
Similar articles
-
Free emboli formation in the wake of bi-leaflet mechanical heart valves and the effects of implantation techniques.J Biomech. 2002 Dec;35(12):1533-40. doi: 10.1016/s0021-9290(02)00093-3. J Biomech. 2002. PMID: 12445606
-
Comparison of the hemodynamic and thrombogenic performance of two bileaflet mechanical heart valves using a CFD/FSI model.J Biomech Eng. 2007 Aug;129(4):558-65. doi: 10.1115/1.2746378. J Biomech Eng. 2007. PMID: 17655477
-
Numerical investigation on the effect of bileaflet mechanical heart valve's implantation tilting angle and aortic root geometry on intermittent regurgitation and platelet activation.Artif Organs. 2020 Feb;44(2):E20-E39. doi: 10.1111/aor.13536. Epub 2019 Aug 4. Artif Organs. 2020. PMID: 31378963
-
Mechanical heart valve cavitation.Expert Rev Med Devices. 2004 Sep;1(1):95-104. doi: 10.1586/17434440.1.1.95. Expert Rev Med Devices. 2004. PMID: 16293013 Review.
-
A review of fluid-structure interaction simulations of prosthetic heart valves.J Long Term Eff Med Implants. 2015;25(1-2):75-93. doi: 10.1615/jlongtermeffmedimplants.2015011791. J Long Term Eff Med Implants. 2015. PMID: 25955008 Review.
Cited by
-
Novel Polymeric Valve for Transcatheter Aortic Valve Replacement Applications: In Vitro Hemodynamic Study.Ann Biomed Eng. 2019 Jan;47(1):113-125. doi: 10.1007/s10439-018-02119-7. Epub 2018 Sep 7. Ann Biomed Eng. 2019. PMID: 30194551 Free PMC article.
-
Lagrangian methods for blood damage estimation in cardiovascular devices--How numerical implementation affects the results.Expert Rev Med Devices. 2016;13(2):113-22. doi: 10.1586/17434440.2016.1133283. Epub 2016 Jan 11. Expert Rev Med Devices. 2016. PMID: 26679833 Free PMC article.
-
Towards non-thrombogenic performance of blood recirculating devices.Ann Biomed Eng. 2010 Mar;38(3):1236-56. doi: 10.1007/s10439-010-9905-9. Epub 2010 Feb 4. Ann Biomed Eng. 2010. PMID: 20131098 Free PMC article. Review.
-
Embolic and bleeding events after modified Bentall procedure in selected patients.Heart. 2007 Jan;93(1):107-12. doi: 10.1136/hrt.2005.086009. Epub 2006 Jun 27. Heart. 2007. PMID: 16803938 Free PMC article.
-
Lagrangian postprocessing of computational hemodynamics.Ann Biomed Eng. 2015 Jan;43(1):41-58. doi: 10.1007/s10439-014-1070-0. Epub 2014 Jul 25. Ann Biomed Eng. 2015. PMID: 25059889 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous